Configuring the Lube System
Lube systems deliver lube to the machine on a schedule. The parameters configure what that schedule is and how the lube is delivered. Accessing the Lube System Parameters 1. Go to the Service -> Maintenance page. 2. Click on the Interface Config button. ...
Drive Wizard Update for the -134 Unlock on GA500 VFD
If you have a Yaskawa GA500 VFD with the high frequency unlock firmware it will have a "-134" on the end of the part number. To connect to these using drive wizard you will need to install this addition to the drive wizard software, First Open drive ...
Single Block Behavior
Purpose This document outlines the expected behavior of the control while Single Block is on. General Behavior Single block will always stop at the end of an executable block and highlight the next executable block, waiting for a Cycle Start before contin...
Yaskawa VFD Capacity Tables
Overview On Yaskawa VFDs, some parameters are scaled differently based on their drive model number. We set the VFD capacity in Mach under the V1000 parameters based on the model number. Set the drive capacity in MachMotion parameter as show below. The part of...
Product Lines No Longer Offered
Thank you for your interest in upgrading with MachMotion! Unfortunately, we are unable to service requests for certain types of new controls. See below for our recommendations on who to go to for service. Machine Type Company Recommendation Cust...
End of Life Support
Definition When replacement parts are no longer available for a product, we officially call it the end of life (EOL). This happens because companies are bought out and stop selling a product, companies shut down, circuit board chips are no longer available, o...
HITACHI P1 VFD Installation
VFD Control Type There are 3 different ways a Hitachi VFD may be connected to MachMotion control: Ethercat, TCP Modbus, or Hardwired. Use the following procedure to determine which method your VFD uses. Then in each section of the manual go to that contro...
Gang Spindle Setup
Overview The gang spindle parameters allow multiple spindles to be locked together in their run state and commanded RPM, compiling all of their feedback into a single unit. In this way, one speed can be set that will be distributed to all spindles in the grou...
Hitachi WJ200 Mini Manual
Hitachi WJ200 Alarm Codes: Programming To be able to program the Hitachi VFD you will either need to change the parameters physically on the VFD or with the Hitachi ProDrive Next software. Hitachi Software Downloads - Software requirements: M...
Hitachi VFD EtherCAT Parameter Settings
This is duplicate documentation from the Hitachi P1 VFD installation manual. Please make all future updates to that documentation. To set up the Hitachi VFD to be commanded by EtherCAT you will need to modify 2 parameters: Parameter Description D...
Copy Mach4 Folder to New Control
This document describes how to copy a Mach4 folder from one machine to another machine. This is useful when you are powering up a similar machine to one you've done previously. It is also used for installing a replacement control. Prerequisites: Mach4/MachMo...
Resistance/Inductance Autodetection (Detect_RL)
The EverCNC drive will try to detect values for motor resistance and inductance when the drive starts up (or when the Nominal_Current parameter changes). This autodetection has limitations, so under some circumstances, it may calculate bad values. You may nee...
EverCNC Titanio Documentation
Manuals and Documentation SW5A9052H221-30 Manufacturer's Website (SW5A9052H221-30C0680) Installation Manual CANopen & EtherCAT DS402 Specification for ’Titanio-Platino-Vanadio’ EVER Drives Overview documentation including display codes Motors ...
Mach Controlled Fixed Memory Auto Tool Changers
Overview The Carousel and Winrack tool changers work off of MachMotion Parameters and an Excel file that can be configured different ways to set all the positions needed for the tool change. Carousel Style Tool Changer Winerack Style Tool Changer
Carousel Style Tool Changer
Overview The MachMotion control has built-in support for Carousel Tool Changers. It works by taking user defined positions and a pre-programmed tool changing sequence and combining them into a tool change routine. Common place safety checks are built in. Th...
EverStudio
EverStudio EverCNC's low-level application for configuring and testing the drive/motor. Connecting to the Drive You need a USB-RS485 adapter for most modern computers without a serial port. The device we have in the shop has these characteristics Ha...
CTB Drive Battery
The following part can easily be found on Amazon.com and is a direct replacement for the absolute encoder battery on the RPKM CTB drives. 3.7V 3600mAh ICR18650 Rechargeable Battery Pack with SM 2P Plug
Sigma SD Servo Spindle Drive Mini Manual
Sigma V - Spindle Drive Critical information: Server Location: M:\Production\Products\Spindles\Spindle Drives\Yaskawa Sigma-V Programming Get the correct software from the local server or Yaskawa's website SigmaWin+ Ver. 5.75 or above must be instal...
Calculate Number Of Motor Poles
To calculate the number of motor poles we need the motors max Hz and RPM. The formula is (120 * Max Hz) / Max RPM. The formula is: (120 * Max Hz) / Max RPM. For example:Motor Max Hz = 300Motor Max RPM = 17400 Example: (120 * 300) / 17400 = 2.068 when rou...
Enable or Disable Encoder Feedback
Open the RapidPath Motion Controller Configuration dialog and select the drive you want to modify. Then select the Drive Parameters tab at the bottom of the page. Find the parameter named Drive_Working_Settings and modify the HEX number on the Edited Value...