General Operation
Axis Directions Y+ is towards the operator X+ is towards the in-feed. Z+ is up and out of the material. Operators There are typically two operators at the machine. One loads doors onto the machine, while the other runs the control. They have a list of pan...
Updating EtherCAT Firmware on Yaskawa Drive
Download the attached firmware files and the manual for TwinCAT. The manual was written for the full version of TwinCAT but will be mostly correct for using the EtherCATCfg.exe Open "EtherCATCfg.exe" from the desktop under "MachMotion Programs and...
Wake and Shake Behavior
EverCNC Titanio - Wake and Shake When the drive powers on, when you enable for the first time, the drive will perform a "feedback sensor calibration" (FSC) that is colloquially referred to as "wake and shake." Theory (Andy, put stuff here) Configuration ...
2000 Series Mill Modbus VFD Spindle and Sub Spindle Setup
This document is not for setting up the multiple grinder heads. This document is a guide for setting up a main spindle and subspindle using the 2000 series VFD parameters. It assumes that the VFDs are already properly programmed and communicating on different...
CHI Support
CHI Support Issues This is a developer page regarding support changes made to CHI that aren't being tracked anywhere else. Changing Offsets (2021-08-01) CHI is reporting that the control is losing/changing offsets that shouldn't be changing. Andrea added s...
Yaskawa Fully Closed Loop Control Control (Dual Loop, Glass Scale, External Encoder)
Setup Calculator Use the calculator on the server to get Yaskawa Drive parameters, and steps per settings for Mach These files are located on the Sharepoint system | Customer Support | Documents/Public Documents/Yaskawa Fully Closed Loop Yaskawa Fully Close...
Yaskawa Programming Drive
Documentation for Crosby group should be on the server under Crosby and customer backups
Calibrating CTB Encoder
Setup Motor setup: Input the motor parameters into the drive according to the motor nameplate Dn.00 = rated current of motor Dn.01 = rated speed of motor Dn.02 = rated voltage of motor Dn.03 = rated power of motor Dn.04 = motor power facto...
Mach Screw Mapping
Screw Mapping Mach 4 (after build 2107, 2014-11-17) implements symmetric, bidirectional mapping (i.e. one map that applies to both directions of travel). Builds after 4780 (2021-11-29) implement asymmetric bidirectional screw mapping (separate maps for positi...
TECO Power and Encoder Cables
400W TECOs Because 400W cables and the original 400W motors without a gearbox are no longer available, use the following process to upgrade a 400W system. If the motor, encoder cable, or power cable fails, you always have to replace all 3. For example, if a...
2000 Series RapidPath Configuration Manual
Introduction RapidPath is MachMotion's EtherCAT motion controller solution. It has integrations for a range of Yaskawa EtherCAT servo drives, VFDs, the Titanio EverCNC stepper drive, and a subset of the Beckhoff I/O devices. It can be licensed for up to 6...
MasterCAM 3x Post (2021, 2022)
Loading a MasterCAM Post processor Please download the post from our tech-exchange as a (.mcam-content) file. This file can be opened with a zip utility or can be just dragged and dropped into the graphic area of Mastercam 2021 or later and the files will be ...
Configuring the Lube System
Lube systems deliver lube to the machine on a schedule. The parameters configure what that schedule is and how the lube is delivered. Accessing the Lube System Parameters 1. Go to the Service -> Maintenance page. 2. Click on the Interface Config button. ...
Drive Wizard Update for the -134 Unlock on GA500 VFD
If you have a Yaskawa GA500 VFD with the high frequency unlock firmware it will have a "-134" on the end of the part number. To connect to these using drive wizard you will need to install this addition to the drive wizard software, First Open drive ...
Single Block Behavior
Purpose This document outlines the expected behavior of the control while Single Block is on. General Behavior Single block will always stop at the end of an executable block and highlight the next executable block, waiting for a Cycle Start before contin...
Yaskawa VFD Capacity Tables
Overview On Yaskawa VFDs, some parameters are scaled differently based on their drive model number. We set the VFD capacity in Mach under the V1000 parameters based on the model number. Set the drive capacity in MachMotion parameter as show below. The part of...
Product Lines No Longer Offered
Thank you for your interest in upgrading with MachMotion! Unfortunately, we are unable to service requests for certain types of new controls. See below for our recommendations on who to go to for service. Machine Type Company Recommendation Cust...
Pin Insertion Machine - SO19250
Overview The pin insertion machine is a small mill for sticking pins into circuit boards. The X/Y table is standard and the Z "axis" is a rotary mechanism for inserting the pins. One 360 degree revolution of the axis creates one punch action that inserts one ...
End of Life Support
Definition When replacement parts are no longer available for a product, we officially call it the end of life (EOL). This happens because companies are bought out and stop selling a product, companies shut down, circuit board chips are no longer available, o...
SO19518: Paper Punch Machine
Overview The machine is a three axis gantry router-type machine. They have the standard X-Y motion and the punch is a rotary W axis. The punch action is done by outputs and hydraulics, not a servo Z axis. Basic operation is to go to a series of positions (X/Y...