VFDs
Yaskawa VFD
GA500
EtherCAT Setup
Parameter | Value | Description |
---|---|---|
B1-01 | 3 | EtherCAT setup - Specific setting |
B1-02 | 3 | EtherCAT setup - Specific setting |
B1-08 | 1 | EtherCAT setup - Specific setting |
F6-01 | 0 | Factory setting or configuration |
F6-03 | 0 | Factory setting or configuration |
F6-14 | 1 | Cannot be changed from the front panel; Use Drive Wizard |
O1-03 | 2 | Frequency Display Unit Selection Set to RPM |
H5-11 | 1 | Comm ENTER command not required setting for A1000, GA500, or GA800 series |
Standard Setup
Setup Load in Mach.
Spindle Load Input Scale Max is calculated as follows:
Spindle Load Input Scale Max = Rated VFD Current X (1/multiplier)
The multiplier is based on the VFD model number:
- 0.01 A units: B001 - B018, 2001 - 2042, 4001 - 4023
- 0.1A units: 2056 - 2082, 4031 - 4060
So a 2021 VFD has a .01 multiplier. Spindle Load Input Scale Max = 21 amps X (1/.01) = 2100.
Also, for the machine to wait for the spindle to reach the desired speed, make sure to check the Wait on spindle to stabilize.