SOURCE - Spindle Setup

Shared Content-Public

Spindle Setup Wiring a Spindle VFD from MachMotion The process for setting up a VFD from MachMotion is extremely simple.  VFD Other Than from MachMotion Any VFD can be wired into the Spindle Control RJ45 jack by cutting the end off of a CAT5 cable and wir...

bsid
666

SOURCE - Limits and Homing _ Configuring Signals

Shared Content-Public

Configuring Signals To set up and wire 24V limit/home switches, follow the steps outlined below. On the menu bar at the top of the screen select Configure->Control. Select the Input Signals Scroll down through the list until you find the differ...

bsid
669

Solenoid or Pump Wiring

Electrical

If you have a RapidPath control, the following concepts apply, but connecting will be a little different. See the installation manual for your kit to see additional detail. Outputs on the breakout board can be used for a variety of control functions. Often th...

bsid
94

Standard Operating Conditions For Electrical and Control Equipment

Electrical

  This document specifies conditions within which MachMotion electrical and control equipment productscan operate. Other conditions may be accommodated with additional engineering. ENVIRONMENTAL Enclosure type: NEMA/UL type 1 (Where enclosure is provide...

bsid
477

SheetCAM Path Rules

Software Sheetcam

SheetCAM path rules can be setup for things like turning off THC control on small parts and slowing down on corners. Creating Code Snippets: Note: The info below is for enabling/disabling the torch height control. You can create custom code in macros to use ...

bsid
639

Yaskawa Sigma 7 Ethercat RapidPath Absolute Encoders Homing

Motors, Drives and VFD's Drives (Servo) - Yaskawa

For setting initial 0 positions on Yaskawa absolute encoders Sigma7 SigmaWin Homing, Zeroing Move machine to where you want 0 to be Jog till hit limit switch then manually turn screw back 1/4 turn Set Torque to as low as you can and still get motion and ...

bsid
644

Sigma-5 Series User Manual

Motors, Drives and VFD's Drives (Servo) - Yaskawa

  File Type Document Name View / Download / Print Sigma-5 Series User Manual Launch                   Keywords:  Yaskawa software guide manual drive servo manufacturer list yaskawa 

bsid
412

SheetCAM Training Information & Tutorials

Software Sheetcam

Tips/Notes: Using the % character in the filename can cause SheetCAM to crash/freeze when importing.   Links to SheetCAM Resources: Install: http://sheetcam.com/Downloads/akp3fldwqh/SheetCam%20TNG%20setup%20V6.0.19.exe   Manual: http://www.sheetcam....

bsid
74

Three Phase Yaskawa Drive and Motor Wiring Diagram Apollo III

Motion Controllers and Breakout Boards Apollo III

    File Type Document Name View / Download / Print Yaskawa Drive and Motor Wiring Diagram Launch     *NOTE: For 480V systems L1C and L2C will be replaced with 24V and 0V(GND) for drive logic.  Connect 24V and 0V accordingly.         ...

bsid
510

HiCON Motor Drive Graph Blank

Motion Controllers and Breakout Boards Apollo III

Description of the problem: The Motor/Drive Response graph is blank when motion is commanded.   Solution: When the HiCON motor/drive graph is blank, this my be caused by Windows Firewall blocking the incoming data.  Start Menu, search "Window Fir...

bsid
32

SOURCE - Axis Setup

Shared Content-Public

Axis Setup Enabling Axes Note: This may already be setup depending on your system. On the menu bar, click Configure->Control. Then select the Motors tab (pictured below). If menu options are grayed out (not active/selectable), click the button to disa...

bsid
665

Wiring Prox Switch Input

Motion Controllers and Breakout Boards Apollo III

  PNP 3-wire example: (see attachment for photo) Brown to C0+ Blue to C0- Black to the input (such as X1, X2, or X3...) https://www.automationdirect.com/adc/Shopping/Catalog/Sensors_-z-_Encoders/Inductive_Proximity_Sensors/12mm_Round_Industrial_Automatio...

bsid
369

X15-02-10 Yaskawa Analog Drive Interface Board Diagram

Motors, Drives and VFD's Drives (Servo) - Yaskawa

  File Type Document Name View / Download / Print Yaskawa Analog Drive Interface Board Diagram Launch     Keywords: cn1 analog yaskawa pinout diagram sheet layout analogio i o i/o board yaskawaboard, X15-02-10

bsid
506

1000 Series Plasma (Mach4) Setup Manual

CNC Machine Operator Manuals

  1 Introduction After mounting the electrical enclosure and the MachMotion CNC control, follow the steps below to setup the MachMotion Torch Height Control. Verify the following components: Torch Height Control Enclosure Torch Slide Voltage Divider B...

bsid
413

SOURCE - Run From Here

Shared Content-Public

Run From Here\File Resume: Use the Up/Down arrows in the gcode file window to select the line to start from  Press the [Run From Here] or [File Resume] button  Select the [Change to Needed Tool] button if applicable (See Image Below) Enter desired value i...

bsid
702

2000 Series Surface Grinder Operating Manual

CNC Machine Operator Manuals Grinder - Surface

1. Introduction 1.1 Control Startup To open the control software double-click on the profile icon on the desktop. 1.2 Overview This manual gives the process for basic operation of the 2000 Series Surface Grinder control. The screen is shown below, foll...

bsid
596

Open Electrical Enclosure With Power ON

Electrical

Here are the steps to open the electrical cabinet without having to shut down power: DANGER: High Voltage Present. Death or Serious Injury Can Occur. You will need a small allen wrench or a small screw driver. Locate the small push pin located near the OFF ...

bsid
336

Programing JSDG2S-20A for 400W TECO Motor

Motors, Drives and VFD's Drives (Servo) - Teco

How to program a JSDG2S-20A drive for a 400W TECO Motor For JSDG2S drives with a 400W motor set Cn030 = H12C1     If it doesn't work, see below. Info below for manually setting motor parameters is no longer needed on standard production drives as of 2021-0...

bsid
325

SOURCE - Warranty Information

Shared Content-Public

Warranty Information MachMotion warranty policy is subject to change. Updated information is available at our website:https://machmotion.com/warranty   The MachMotion Teamhttp://www.machmotion.com14518 County Road 7240, Newburg, MO 65550(573) 368-7399 • F...

bsid
677

Drive Error List - Teco

Motors, Drives and VFD's Drives (Servo) - Teco

*Alarms in table below noted with asterisk (*) have additional important info below the table Display Name Cause Action AL-01* Under-Voltage The main circuit voltage is below its minimum specified value. (190Vac) Use a Voltmeter to check whet...

bsid
107
Teco Alarms
Alarms
teco alarms
alarms
drive fault
drive alarm
al-01
al-02
al-03
al-04