Write Base Parameters to Yaskawa VFD
Install/Open Yaskawa DriveWizard and Change IP
1) IfOpen Yaskawathe MachMotion Programs and Drivers shortcut on the desktop and select Drive Wizard is already on the control, open the programIndustrial and skip to step 5. If the drive wizard is not installed on the control, proceed with step 2.
2) On the MachMotion server, Go to Production->Products->Spindles->VFDs->Yaskawa->V1000->sw.dw.30.
3) Move "setup" to the desktop of the controller and double click to install.
4) After running the install, open "DriveWizard Industrial." Check lower right corner of screen for updates.
5) Click on "Drive Selection & Communication Setup."
6) Change the first drop down to V1000. Select "Ethernet" option. Click "Modify" and change IP address in "Direct IP Connection" window. IP needs to match the drive you're connecting to (192.168.208.90, 192.168.208.91, etc.)
7) Go back to "Drive Selection."
8) Click "Connect to Drive / Go Online."
Write Base Parameters to Yaskawa VFD
1) On the MachMotion server, Go to Production->Products->Spindles->VFDs->Yaskawa->V1000->Drive Parameters.
2) Select the "YDWIProj" file you want and drag it to the desktop of the controller.
3) Once connected to the drive in the Yaskawa DriveWizard, click on "Open Project."
4) Select the project you just placed on the desktop.
5) Once loaded, click "Write Parameters" to send to VFD.