Skip to main content

Trio Drive Setup

Programming

Download Motion Perfect (Motion Program Development System) from Trio's website (https://www.triomotion.com/system/downloadPage.php?location=%2Fsoftware) . 

Install on your control. 

Program with default parameters. 

Main used parameters: 

Parameter MachMotion Default Notes
Pn007.1



1

Set to 0 for single phase.
-for 1.5kW drive will apply an 80% de-rate
-or 2.0kW and 3.0kW single-phase is not supported


Set to 1 for three phase. 

Pn002.2

0

0 [Default] Use the encoder as an absolute encoder (requires encoder battery)
1 Use the encoder as an incremental encoder




Reset Absolute Encoders

Follow the procedures below when powering up an absolute encoder system. 

image.png

image.png

image.png

Wiring