TECO Power and Encoder Cables

400W TECOs

Because 400W cables and the original 400W motors without a gearbox are no longer available, use the following process to upgrade a 400W system. 

If the motor, encoder cable, or power cable fails, you always have to replace all 3. For example, if a MT-040-302 (6CC401G-3DEBW-U) motor fails, you have to replace the motor, encoder cable, and power cable with completely new part numbers. 

 

Part NumberMFG Part NumberReplacement PlanNotes
MT-040-302-03 

Option 1: Replace with 400W brake motor with original connectors

MT-040-302B-03

CBT-075-05 or

CBT-075-10

Must wire brake cable directly to 24VDC. Polarity does not matter.

Must be enough space for a 132mm motor (36.6mm longer than the original).

 

 

 

Option 2: Replace with new motor with new connectors

MT-040-302

(MFG: 6CC401G-3DEBWAS)

CPT-040-XX (03,05,10,20)

Select whatever length needed.

 

 

 

 

 

 
MT-040-302B-03DTS6C401C3AWBU000 STOCK*
MT-040-302G-03DTS6C401C3AWGUUA0 STOCK*

*In the future, if we run out of inventory, we may have to sell MT-040-302B and MT-040-302G. 


Cables

Part NumberMFG Part NumberReplacement PartNotes
CPT-040-05-XX   
    
    
   STOCK
   STOCK

 

 

 

750W TECOs

For 750W motors we still have motors in stock, but we don't have the original power and encoder cables. So if a motor fails you can replace the motor. If the cable fails, you must repair the cable or replace the motor, power cable, and encoder cable. 

Part NumberMFG Part NumberReplacement PartNotes
MT-075-302DTSB08751C2NTCDL1 

STOCK*

 

 

MT-075-302B   
    
    
    

*In the future, if we run out of inventory, we may have to sell JSMA-PLC08ABK (TSB08751C-2NT3-D). Shaft size is 16mm instead of 5/8". 

 

Cables

Part NumberMFG Part NumberReplacement PartNotes
CBT-075-05DTY3FCB05MBRKCBD0 STOCK
CET-075-05DTY3FCB05M0PGCBD0 STOCK
CPT-075-05DTY3FCB05MUVWCBD0 STOCK
CBT-075-010DTY3FCB10MBRKCBD0 STOCK