Skip to main content

Drive Error List - Leadshine

Errors Not on Table

Codes that have shown up but are not listed on the error table below or with information.

  • E570 which is expected while the system is not enabled. It will clear once the safety relay is active and it receives that input.
  • E152 will show on the face of the drive and Mach4 will throw up an "Unrecognized alarm code: 0x00007323". This has been noticed to be when the motor is not wired correctly or just not connected at all.

Below are the error codes and alarm clearing taken from the manual for CS3E_User_Manual_V1.5 and CS3E-D1008. Both of these pdf files can be found on their website and on the server at \\svr1\MachMotion\Production\Products\Drives-Stepper\Leadshine\Manuals

Error Code Table

(1) Object 0x3FFE+01 indicates the current failure alarm, and other sub-index indications are historical alarms.
(2) Object 0x1001 and 0x603F indicate the current failure alarm, The error code read by 0x603F is IEC 61800 specification; the error
code read by 0x1001 is CIA specification.
(3) Error code read by some master station is displayed in decimal. At this time, please convert it to hexadecimal and then refer to the error code table as below. For example, the master station reports error code of 8721, the corresponding hexadecimal number is 0x2211, so the alarm information in the reference table is over-current alarm.

0x3FFE Value0x603F ValueDescriptionTrouble Shooting
0x0e00x2211Over-current1. Check whether the wiring is short-circuited, or the motor is short-circuited. 2. Switch power supply alarm caused, replace other power supply for a try.
0x0c00x3211Over-voltage1. Check the voltage of power supply;
2. If over-voltage occurs in motion, the acceleration and deceleration time
can be increased
0x0a00x3150EEPROM error in phase A
1. Reset parameters to the factory and restart power supply 2. If it still exists, the hardware failure
0x0a10x3151EEPROM error in phase B
0x1a00x8402Over-speed1. Reduce command speed value; 2. Write 0x10 to the object 0x2056 to clear the alarm.
0x2400x5530Save error1. Reset parameters to the factory and restart power supply 2. If it still exists, the hardware failure
0x2600x7329Limit switched alarmRefer to 0x22A9+00
0x5700x5441Quick stop alarmRefer to 0x22B4+00
0x5f00x7122Auto-tuning error1. Restart the drive; 2. If it still exists, disable auto-tuning by 0x2013
-0x7321Encoder wring error1. The drive is not connected to a motor; 2. If alarm is occurred when connect a motor, please check the encoder wiring or a cable break.
0x8160x8216Invalid mailbox configuration in pre-operation state
Check the network cable
0x81b0x821BWatchdog timeout
Check the network cable
-0x8611Position following error1. Set the value of Object 2024h to “0” to make motor run in open loop mode, If alarm disappears, it means encoder wiring error; 2. Motor torque is not enough or motor speed is too high;
0x8360x8736Invalid DC synchronization periodDecrease the value of the synchronization period or increase the value of 0x5400+02
0x8700x5201Unsupported operation modeCheck the value of 0x6061 and correct it to the supported operation mode;
0x8010x8201ESM state machine transition failed
Alarms related to the master station, without accurate solution.
0x8020x5510Memory overflow
0x8070x8207The mapping object does not exist
0x8080x8208PDO mapping object length error
0x8090x8209PDO mapping object has no mapping attribute
0x8110xA001Invalid ESM conversion request
0x8120xA002Unknown ESM conversion request
0x8130x8213Boot state request protection
0x8150x8215Email configuration with invalid boot status
0x8180x8211No valid input data
0x8190x8212No valid output data
0x81c0x821CInvalid sync manager type
0x81d0x821DInvalid output configuration
0x81e0x821EInvalid input configuration
0x8210xA003Waiting for the initial state of ESM
0x8220xA004Waiting for ESM pre-operation state
0x8230xA005Waiting for ESM safe operation status
0x8240x8224Invalid process data input mapping
0x8250x8225Invalid process data output mapping
0x8270x8727Free running mode is not supported
0x8280x8728Does not support synchronous mode
0x82b0x8210Invalid input and output
0x82c0x872CFatal sync error
0x82d0x872DNo synchronization errors
0x82e0x872ESynchronization period is too small
0x8300x8730Invalid DC synchronization configuration
0x8320x8732DC phase locked loop failure
0x8330x8733DC sync IO error
0x8340x8734DC synchronization timeout
0x8350x8735Invalid DC cycle
0x8500x5550EEPROM inaccessible
0x8510x5551EEPROM error
0x8520x5552The hardware is not ready

 

Alarm Clearing

After the CS3E drive alarms, the power should be cut off first to check the fault, especially the over-current and over-voltage faults.
Some alarms (except over-voltage and over-current) can be cleared when the drive is holding on, the step is as follows:

  • Write 0x80 (decimal 128) to the object 0x6040 to clear the current alarm (except over-voltage and over-current). This method is recommended as a priority;
  • Or write 1 to the object 0x2093 to clear the historical alarm records. At this time, all sub-indexes of 0x3FFE are cleared;