IO6 to Apollo I Conversion
Outputs:
Enable / Charge Pump 2-17
Output 1 enabled 2-14 (for spindle CW. can change output signal, just need to also match it in the spindle config tab)
Output 2 enabled 2-16 (for spindle CCW. can change output signal, just need to also match it in the spindle config tab)
Inputs:
E-stop 2-15
Drive Fault 1-10
Motor Outputs:
Spindle: enabled 1-0 Step Low 2-0
Spindle Setup Tab:
Click on the Spindle Setup tab. Make sure the check box Disable Spindle Relays is unchecked and that the Clockwise Output # is 1 and the Counterclockwise Output # is 2. Also, select the check box PWM Control and set the PWM Base Freq. to 100
Additional Resources (if needed):
See attached IO6 to Apollo I sheet for cross refernce
https://support.machmotion.com/books/motion-controllers/page/apollo-i-user-manual---mach3
https://machmotion.com/documentation/Motion%20Controllers/IO6/IO6%20to%20Apollo%20I%20Conversion%20Chart.pdf