2000 Series Waterjet Operating Manual
{{@672}}
Introduction
Overview
This manual gives an overview for the basic operation of the MachMotion Waterjet control. The screen is shown below, followed by a brief summary of the different features of the screen. The numbers shown in the screenshot refers to a brief description below the image.
Control Startup
To open the control software, double-click on the profile icon on the desktop.
Control Screen Overview
G-code Tab
- Toolpath
- Regen Toolpath: refresh the displayed toolpath
- View Top: top view of the part
- View ISO: side view of the part
- File
- Recent: load a recently loaded G-code program
- Load: load a G-code program from the computer
- Edit: edit the G-code program currently loaded into the control
- Close: close the G-code program that is currently loaded into the control
- Advanced
- Single Block: when active, the control will go line by line through the G-code program when the operator presses [Cycle Start]
- Block Delete: when active, the control will skip the lines in the G-code program indicated by their block level
- Part Counter: displays the number of parts that the machine has produced
- M1 OPT Stop: when active, the control will stop at any M1 command in the G-code program and wait for the operator to press [Cycle Start]
- Dry Run: when active, the control will ignore all mist or flood commands
- M-S-T Lock: when active, the control will ignore all M-codes, jet commands, and tool commands
- File Resume: allows the operator to select a line of G-code to start the program from and makes the control ready to run from that location
- Collapse: minimizes the advanced section to only show M1 OPT Stop and File Resume
- Status
- Status: displays the most recent message
- State: displays the current control state
- Cycle Time: displays how long the G-code program has been running
- Date: displays the current date and time of the control
- Axis Digital Readouts
- For each axis on the control, there is the following:
- A DRO displaying the current position
- A DRO displaying the distance left to travel
- A gauge displaying the current load on the axis
- Indication that the axis has not been homed if the axis letter is flashing
- MDI: opens or closes a window for G-code commands
- Viewing Part: toggles the axis position DROs between machine coordinates and the current fixture coordinates
- For each axis on the control, there is the following:
- Active Modals
- Active Offset: displays the current fixture offset
- Tool Display
- T: displays the current selected tool number
- Next Tool: displays the next tool to be used by the G-code program
- Diameter: displays the stored diameter of the current tool
- Length: displays the stored length of the current tool
- Feedrate Display
- F: displays the current commanded feedrate
- Feed OV: displays the current feedrate override percentage (0-300%)
- Rapid OV: displays the current rapid override percentage (0-100%)
- Jet Display
- Pierce Delay: displays the current pierce delay while jets are turning on in seconds
- Abrasive Rate: shows the rate of abrasive output at a percentage of ability
- High Pressure: toggles if the jets operate in high pressure mode
- Cut Recovery: moves machine to the closest point on the path of the loaded G-code program and asks for confirmation to start cutting from there
- Station 1 - 4: toggles which jet stations will turn on when jets are on and which stations also use abrasive
Fixtures Tab
- Edit
- Edit Offsets: edit the active fixture offsets
- Fixtures
- Fixture Table: view and edit the fixture table for all fixtures
- Align
- Plate Alignment: open plate alignment wizard to rotate machine for crooked plate material
- Fixture Offset
- Displays the current fixture offset for each axis
- Work Shift Offset
- Displays the current work shift offset for each axis and allows the operator to edit them
- G52 Offset
- Displays the current G52 offset for each axis
- Axis Digital Readouts
- For each axis on the control, there is the following:
- A DRO that displays the current position and allows to edit the current fixture offset
- A DRO displaying the distance left to travel
- A gauge displaying the current load on the axis
- A button to zero the current fixture offset to the current location
- For each axis on the control, there is the following:
Service Tab
Maintenance Tab
- Limits
- Soft Limits: toggles software limits on or off
- Limit Override: toggles to allow for the machine to move off a limit switch
- PLC
- Reset Pocket: only used for tool changers
- PLC Sequence
- Enable
- Disable: toggles if the machine is enabled or disabled
- Settings
- Interface Config: opens the MachMotion parameters for editing
- Motion Controller: opens the configuration for the active motion controller
- Screen Config: opens the configuration to change the colors and password protect aspects of the screen
- Industrial Theme: applies standard colors to screen objects
- Toggle Menu: opens settings for top menu bar
- Compile Scripts: refreshes programming scripts
- Homing
- Home X: sends X axis to do its homing routine
- Home Y: sends Y axis to do its homing routine
- Home Z: sends Z axis to do its homing routine
- Home All: all axes do their homing routine in their configured order
- Support
- Remote Support: starts a remote support session with the MachMotion technical support team
- Support: opens the online MachMotion Support Library
- Updates: checks for updates to the MachMotion control software
- History: view the operator message history
- User
- Logout: logs out of the Windows username
- Power: turns off the computer
Dashboard Tab
The dashboard is used to make the control just the way you want it! For more information, read here.
Machine I/O Tab
This tab is used for diagnostics and shows all enabled machine signals.
Homing
To home the machine, begin by pressing the [Reset] button. Then navigate to the [Service/Maintenance] tab and press [Home All]. There is an optional parameter to prompt the user to home the machine on startup.
Programmed Movement
MDI
To command a movement using the MDI feature, press the [MDI] button.
G-code
The primary method of commanding motion is using G-code files. G-code files can be hand written, generated by a wizard, or generated from CAD files using a CAM program.
Toolpath Screen
The controls to manipulate the toolpath screen are as follows:
-
- Zoom – Right click with the mouse and move mouse up/down or using the scroll wheel on the mouse
- Rotate – Left click with the mouse and rotate the part by moving the mouse
- Pan – Press and hold [Ctrl] on the keyboard and left click with the mouse, then pan by moving the mouse (one-hand control option is to use left and right mouse click and move the mouse. No [Ctrl] press needed)
Cut Recovery
The control comes with a feature that allows the user to jog the machine to anywhere on the part and start running the G-code program from there. Operation of this feature is as follows:
- Jog the machine close to the position to start from. Using the toolpath on the screen may help the operator get close to the path.
- Press [Cut Recovery] in the Jet Display group. The operator will be asked to press [Cycle Start] to confirm the motion on to the path.
- The control will evaluate if the jets should be on at this point in the file, and then ask the operator to press [Cycle Start] to confirm running the file from this point.
Jet Control
G-code Jet Commands
The jet is controlled with with M-codes M3 (On) and M5 (Off). These commands can be done in G-code or through MDI. Pierce, abrasive and High Pressure timers can all be set manually or set while calling the M3. Values set with M3 will override values set manually. The command should look like this: M3 P H E
P is pierce delay, H is pressure delay and E is abrasive delay. Time will be set in seconds. Example: M3 P2 H3 will turn on the jet with a 2 second delay and pressure on for 3 seconds. E is not called in this example so it will default to the user settings instead of what is called in the G-Code.
Manual Jet Control
To control the jet separately from G-code, use the spindle controls on the operator panel. The buttons for [FWD] and [REV] will both turn the jet on, while the [STOP] button will turn the jet off.
Jet Run Settings
The control supports up to four jets. A jet must be enabled in the parameters by mapping the appropriate outputs to control the pressure on, high pressure, and abrasive.
When commanding the jets on, the selection of which jets turn on is done on the screen. Each station can be selected individually if it should turn on and if it should use abrasive. All stations that are on will operate in high-pressure mode or not together. All stations using abrasive will use abrasive at the same rate. All stations that turn on will use the same pressure, abrasive, and pierce delays.
Configuring Jet Parameters
The MachMotion parameters can be accessed on the [Service/Maintenance] tab by pressing the [Interface Config] button.
In the [Jet/General] section, are parameters for the number of jets and the delay times to use while turning the jets on. The control supports up to four jet stations that are controlled simultaneously. The selection of which jets turn on is done on the screen.
For each jet, outputs must be mapped for turning on their pressure, abrasive, and high pressure states in the [Jet/Output] section. If the abrasive is a servo motor feed system, then the servo motor needs to be enabled in the [Jet/Abrasive] section and the appropriate axis ID assigned to it. The axis ID is the axis number that the motor is mapped to in Mach config. The axis must be an OB axis (axes 6-11).
To allow for jet height control while the machine is cutting, an axis must be mapped to the Z override axis. This axis ID must be an OB axis (axes 6-11) and must not be the same as an abrasive motor. The control must be restarted for changes to this value to take effect.
Jet On and Off Sequence
All enabled jets will turn on or off the outputs at the same time.
Jets On Diagram (M3)

Jets Off Diagram (M5)

Delay Descriptions:
1. Jet Abrasive Line Delay (ms) “JetAbrasiveDelay”- Turns Jet and Abrasive on at the same time. Then applies the delay. Identical to “Jet Abrasive On Delay” and “Jet Pierce Delay”.
2. Jet Abrasive On Delay (sec) “JetAbrasiveOnDelay”- Turns Jet and Abrasive on at the same time. Then applies the delay. Identical to “Jet Abrasive Line Delay” and “Jet Pierce Delay”.
3. Jet Abrasive Off Delay (sec) “JetAbrasiveOffDelay”- Turns off Abrasive, applies delay, Turns off Jets. Identical to "Jet Abrasive Purge Line Delay"
4. Jet Abrasive Purge line Delay (ms) “JetAbrasivePurgeDelay”- Turns off Abrasive, applies delay, Turns off Jets. Identical to “Jet Abrasive Off Delay”.
5. Jet Pre-Off Delay (ms) “JetPreOffDelay”- Applies delay, then turns Jet off.
6. Jet Off Delay (ms) “JetOffDelay”- Turns Jet off, then applies delay.
7. Jet Pierce Delay (sec) ““JetPierceDelay”- Turns Jet on, then applies delay.
8. Jet Pressure Delay (ms) “JetPressureDelay”- Turns Jet on, then applies delay, then turns on Abrasive.
9. Jet High Pressure Delay (ms) “JetHighPressureDelay”- When “High Pressure Toggle” is high, it applies the delay, then turns on Jet and Abrasive. No yellow wait bar appears.
10. Jet Pump On Delay (ms) “JetPumpAutoOnDelay”- Turns on Pump, applies delay, flashes button until delay is over
Intensifier Control
Overview
The MachMotion waterjet control supports intensifier pump systems for high-pressure waterjet cutting. The intensifier control system provides automatic monitoring and safety protection for critical components including check valves, oil temperature, bleed-down systems, and water pressure. The control can manage up to two independent intensifier units with comprehensive monitoring and diagnostic capabilities.
Intensifier Safety Monitoring
The control continuously monitors the intensifier system and will automatically disable the machine or alert the operator when safety conditions are detected. All intensifier monitoring systems integrate with the Global Monitoring System (GMS) to provide real-time alerts and automatic protective actions.
Temperature Monitoring
Check Valve Temperature Alarms
- Each intensifier supports monitoring for two check valves
- When a check valve temperature alarm is triggered, the machine will immediately disable and alert the operator
- This protects the check valves from thermal damage during operation
- Action: Machine disables automatically - Check the cooling system and allow check valves to cool before resuming operation
Oil Temperature Warning
- Provides early notification when intensifier oil temperature is elevated but still within safe operating range
- Allows the operator to take corrective action before reaching critical temperature
- The machine will continue to operate but displays a warning notification
- Only monitors when the jet pump is running (pressure ramping or at full pressure)
- Action: Monitor the oil temperature - Consider reducing duty cycle or checking oil cooling system
Oil Temperature Alarm
- Triggers when oil temperature reaches critical levels
- Machine will immediately disable to prevent damage to the intensifier
- Only monitors when the jet pump is running (pressure ramping or at full pressure)
- Action: Machine disables automatically - Allow oil to cool and inspect cooling system before resuming
Bleed Down Over Temperature Alarm
- Monitors the temperature of the bleed-down valve system
- When temperature exceeds safe limits, the machine disables automatically
- Action: Machine disables automatically - Check bleed-down valve operation and cooling
Oil Level Monitoring
Oil Low Alarm
- Monitors the hydraulic oil level in the intensifier reservoir
- When oil level drops below minimum safe operating level, machine disables immediately
- Action: Machine disables automatically - Check for leaks and refill oil to proper level before resuming
Water Pressure Monitoring
Inlet Water Pressure Low Warning
- Provides early notification when inlet water pressure drops below optimal level
- Machine continues to operate but alerts the operator
- Only monitors when the jet pump is running (pressure ramping or at full pressure)
- Action: Check water supply pressure and flow - Address before pressure drops further
Inlet Water Pressure Low Alarm
- Triggers when inlet water pressure is insufficient for safe intensifier operation
- Machine will immediately disable to prevent damage
- Only monitors when the jet pump is running (pressure ramping or at full pressure)
- Action: Machine disables automatically - Verify water supply is adequate and pressure sensor is functioning
Stroke Monitoring
Stroke Over Speed Alarm
- Monitors the stroke rate of each intensifier
- Triggers when stroke rate exceeds the configured maximum safe speed
- Prevents damage from excessive cycling speed
- Machine will disable automatically when detected
- Action: Machine disables automatically - Check for pressure control issues or improper settings
Stroke Stall Alarm
- Monitors for insufficient stroke rate indicating stalled operation
- Triggers when stroke rate falls below the configured minimum
- Detects mechanical binding or insufficient pressure
- Machine will disable automatically when detected
- Action: Machine disables automatically - Inspect for mechanical issues or pressure problems
Configuring Intensifier Parameters
The intensifier parameters can be accessed on the [Service/Maintenance] tab by pressing the [Interface Config] button. Navigate to the Jet/Intensifier section.
Input/Output Configuration
For each intensifier unit, the following inputs and outputs must be mapped:
Intensifier 1 & 2 Shift Control:
- Shift Left Input - Confirms intensifier has shifted to left position
- Shift Left Output - Commands intensifier to shift left
- Shift Right Input - Confirms intensifier has shifted to right position
- Shift Right Output - Commands intensifier to shift right
Temperature Monitoring Inputs:
- Check Valve 1 Temperature Alarm Input - Digital input from check valve 1 temperature switch
- Check Valve 2 Temperature Alarm Input - Digital input from check valve 2 temperature switch
- Oil Temperature Warning Input - Digital input from oil temperature warning sensor
- Oil Temperature Alarm Input - Digital input from oil temperature alarm sensor
- Bleed Down Over Temperature Alarm Input - Digital input from bleed-down temperature sensor
Pressure and Level Monitoring Inputs:
- Inlet Water Pressure Low Warning Input - Digital input from water pressure warning sensor
- Inlet Water Pressure Low Alarm Input - Digital input from water pressure alarm sensor
- Oil Low Alarm Input - Digital input from oil level sensor
Control Outputs:
- Bleed Down Valve Output - Controls the bleed-down valve solenoid
- Boost Pump Output - Controls the boost pump motor
- Water Cooling Output - Controls intensifier cooling system
- Inlet Water Valve Output - Controls inlet water supply valve
Stroke Monitoring:
- Stroke Over Speed Alarm (Intensifier 1 & 2) - Maximum stroke rate threshold before triggering over-speed protection
- Stroke Stall Alarm (Intensifier 1 & 2) - Minimum stroke rate threshold before triggering stall protection
Timing Parameters
Debounce Times (seconds):
These parameters prevent false alarms from momentary sensor fluctuations.
- Jet Intensifier Oil Temp Warning Debounce - Time the oil temperature warning input must be active before triggering warning (default: 1.0 seconds)
- Jet Intensifier Oil Temp Alarm Debounce - Time the oil temperature alarm input must be active before triggering alarm (default: 1.0 seconds)
- Jet Intensifier Inlet Water Pressure Low Warning Debounce - Time the water pressure warning input must be active before triggering warning (default: 1.0 seconds)
- Jet Intensifier Inlet Water Pressure Low Alarm Debounce - Time the water pressure alarm input must be active before triggering alarm (default: 1.0 seconds)
Startup and Shutdown Delays:
- Jet Intensifier Inlet Water Pressure Delay - When inlet water pressure sensor is not mapped, this delay (in seconds) is applied after opening the inlet water valve to allow pressure to stabilize (default: 2.0 seconds)
- Jet Intensifier Inlet Water Pressure Wait On Input Timeout - When inlet water pressure sensor is mapped, maximum time (in seconds) to wait for good water pressure signal during startup. If timeout is exceeded, an alarm is triggered (default: 10.0 seconds)
- Jet Intensifier Water Cooling Off Delay - Time (in seconds) to keep cooling water running after intensifier shuts down to ensure proper cool-down (default: 60.0 seconds)
Operating the Intensifier
Startup Sequence
When the jet pump is commanded on (M174), the control will automatically execute the following sequence:
Pump Status: STARTING
- Bleed Down Valve - CLOSES
- The bleed-down valve closes to prepare the system for pressurization
- Inlet Water Valve - OPENS
- Inlet water valve opens to supply water to the intensifier
Pump Status: INLET WATER ON
- Boost Pump - STARTS
- Boost pump motor starts to pre-pressurize the water supply
- Water Cooling - STARTS
- Water cooling system activates to maintain proper operating temperature
- Inlet Water Pressure Check
- If pressure sensor is mapped: Waits for inlet water pressure good signal (timeout per configured parameter)
- If pressure sensor is not mapped: Delays for configured time to allow pressure to stabilize
- If pressure is not detected within timeout period, triggers "Intensifier Inlet Water Low Pressure Alarm" and machine disables
Pump Status: STARTING MOTOR
- Pump Motor Output - ACTIVATES
- Main pump motor output is turned on
- Momentary On Output - PULSES (if mapped)
- If configured, sends a momentary pulse to start the pump motor (350ms pulse)
- Pump On Delay
- Waits for configured pump delay time to allow motor to reach operating speed
- Displays progress bar: "Waiting for Jet Pump Delay"
- Pump Is On Input Check (if mapped)
- Waits for confirmation signal that pump motor is running
- Timeout: 60 seconds
- Displays: "Waiting for Jet Pump to turn On"
Pump Status: MOTOR UP TO SPEED
- Pressure Ramp Delay
- Waits for configured ramp delay time as pressure builds
- Displays progress bar: "Waiting for Pressure Ramp Up Time"
Pump Status: PRESSURE RAMPING DONE
- Safety Monitoring Active
- All temperature, pressure, and stroke monitoring systems are now active
- Ready for cutting operations
Shutdown Sequence
When the jet pump is commanded off (M175), the control will automatically execute the following sequence:
- Pump Motor Output - DEACTIVATES
- Main pump motor output is turned off
- Momentary Off Output - PULSES (if mapped)
- If configured, sends a momentary pulse to stop the pump motor (350ms pulse)
- Bleed Down Valve - OPENS
- Bleed-down valve opens to safely depressurize the system
- Boost Pump - STOPS
- Boost pump motor is turned off
- Inlet Water Valve - CLOSES
- Inlet water valve closes to stop water supply
Pump Status: OFF
- Water Cooling - CONTINUES RUNNING
- Water cooling system remains active for the configured cool-down period
- Default: 60 seconds after pump shutdown
- This ensures the intensifier cools down properly before cooling water stops
- Water Cooling - STOPS (after delay)
- After the configured delay period elapses, cooling water is turned off
- Cool-down timer is managed automatically by the control
Troubleshooting Intensifier Alarms
| Alarm/Warning | Possible Causes | Corrective Action |
| Check Valve Temperature Alarm | Inadequate cooling, excessive duty cycle, failing check valve | Check cooling flow, reduce duty cycle, inspect check valve |
| Oil Temperature Warning/Alarm | Low oil level, insufficient cooling, excessive ambient temperature | Check oil level, verify cooling system operation, improve ventilation |
| Oil Low Alarm | Oil leak, insufficient initial fill | Inspect for leaks, refill to proper level |
| Inlet Water Pressure Warning/Alarm | Low supply pressure, clogged filter, failing pressure sensor | Check supply pressure, replace filters, test sensor |
| Bleed Down Over Temperature | Excessive bleed-down frequency, valve malfunction | Allow cool-down time between cycles, inspect valve operation |
| Stroke Over Speed Alarm | Pressure control malfunction, improper parameter settings | Check pressure regulation system, verify stroke speed settings |
| Stroke Stall Alarm | Mechanical binding, insufficient inlet pressure, low oil level | Inspect for obstructions, check water supply and boost pump, check oil level |
Notes
- All monitoring systems only activate when the pump status indicates the pump is running (MOTOR UP TO SPEED or PRESSURE RAMPING DONE)
- The water cooling delay timer begins when the pump status changes to OFF
- Debounce times help prevent nuisance alarms from momentary sensor fluctuations
- Always verify all safety sensors are functioning properly before starting operations
- Review alarm history in Global Monitoring System diagnostics for troubleshooting patterns
M-Codes
|
M3 |
Jets On, Optional values: P = Pierce Delay (sec) E = Abrasive Delay (sec) H = Pressure Delay (sec) K = Abrasive Rate (0-100%) S = Pressure (psi) overwrites #9000 |
| M5 | Jets Off |
| M170 | Jets Abrasive Master Enable On |
| M171 | Jets Abrasive Master Enable Off |
| M172 | Jets High Pressure On |
| M173 | Jets High Pressure Off |
| M174 |
Jet Pump On
S = Pressure (psi) overwrites #9000 |
| M175 | Jet Pump Off |
G-Code Parameters
|
1910 |
Wiggle Piercing Circles During Pierce Delay (1 = On, 0 = Off) |
| 1911 | Wiggle Piercing Number of Loops |
| 1912 | Wiggle Piercing Diameter |
| 1913 | Wiggle Piercing Feedrate |
Pound Variables
|
9000 |
Commanded Jet Pressure (psi) |
Intensifier pump
You can set values between 1 and 10 seconds for turning the intensifier on and off. In [Configure | Control | Spindle tab] use the Accel Time for turning it on, and the Decel Time for turning it off.
Appendix