Follow these steps to set it up:
- Copy the files from C:\Mach4\Profiles\Router\Macros\Scripts to the control
- Copy these to C:\Mach4\Plugins
- DataCollector.sig
- DataCollector.m4pw
- Copy these to C:\Mach4\Plugins
- Enable the plugin “DataCollector – MachMotion”
- Restart Mach4
- Go to Configure -> Plugins -> Data Collector
- Select Add
- Setup the configuration as follows
- Press Save
- Copy the files from C:\Mach4\Profiles\Router\Macros\Scripts to the control
- Copy this to “C:\Mach4\Profiles\Router\Macros\Scripts”
- UserGUIModule.mcs
- Note: if you do it earlier you will get errors while loading the screen
- Copy this to “C:\Mach4\Profiles\Router\Macros\Scripts”
Notes
- Currently it is hard coded to wait for 100 hours