Skip to main content

Data Collector

Follow these steps to set it up:

  1. Copy the files from C:\Mach4\Profiles\Router\Macros\Scripts to the control
    1. Copy these to C:\Mach4\Plugins
      1. DataCollector.sig
      2. DataCollector.m4pw

Datalogging-plugin.png

  1. Enable the plugin “DataCollector – MachMotion”
  2. Restart Mach4
  3. Go to Configure -> Plugins -> Data Collector
    1. Select Add
    2. Setup the configuration as follows

 Data-configuration.png

  1. Press Save
  2. Copy the files from C:\Mach4\Profiles\Router\Macros\Scripts to the control
    1. Copy this to “C:\Mach4\Profiles\Router\Macros\Scripts”
      1. mcs
      2. Note: if you do it earlier you will get errors while loading the screen

Notes

  1. Currently it is hard coded to wait for 100 hours