Skip to main content

Updating TECO Motor Codes

 

To check the current motor code in a TECO servo drive, press the Mode button until you see dn-01. Use the up arrow buttons to set the drive to dn-08. Hold down the Enter button until the screen changes. Verify that the motor code is correct according to the table below.

If dn-08 is not setup correctly, you need to enter in the correct code. Follow the procedure below.  

Note: By briefly pressing the Enter button you can edit the other digits (ten’s place, hundred’s place, etc).

  1. Press the Mode button until you get to Cn001. Using the up and down arrow keys, set the drive to Cn030. Hold down the Enter button and the drive will display the current value.
  2. Set the display to the correct motor code based on the table below. Hold down the Enter button and the display will return to Cn030.
  3. Remove power from the drive until the screen completely goes blank. Then power it back up.
  4. Press the Mode button until you get to Cn001. Set the drive to Cn029. Hold down the Enter button and the drive will display the current value.
  5. Set the display to Hold down the Enter button and the display will return to Cn029.
  6. Remove power from the drive until the screen completely goes blank. Then power it back up.
  7. Set the following parameters:

Hn504 = 4

Hn505 = 5

CN035 = 15

 

Programming is complete.

Standard Motor Codes

Motor Size

Motor Code

400W

3000 RPM

H1220

750W

3000 RPM

H1211

750W

Break

 

1000W

1000 RPM

H1321

1000W

2000 RPM

H1331

2000W

2000 RPM

H1541

3000W

2000 RPM

H1711

3000W

3000 RPM

H1721