Skip to main content

Sigma SD Servo Spindle Drive Mini Manual

Sigma V - Spindle Drive

Critical information:



Programing the Drive

Load the Motor Config file.

You will need to load your particular motor file from PD.SIGMASD.01.zip.

image.png

Until you load the Motor config file, you may see the A.052 Alarm.

After loading the motor config file, then copy in the main drive parameters file.

The parameters file must be loaded AFTER the motor config file or else you may see the A.910 Alarm.

Additional Notes:
Parameter Default Changed to
PN800 100 10
PN802 100

10

PN82b.0 0

1

PN82c.0 0

1

ESP = the safety relay circuit to reduce the speed when stopping in estop circuit. 


Spindle Drive Example - Analog Pulse

Screen Shot 2022-09-04 at 9.03.16 PM.png


Motor Wiring Example:

IMG_3159.JPEG


Wiring Overview - Motor to Drive

image.png

 

Ethercat capable drives

When setting up if there is no drive parameter file to pull from then these will be the necessary ones to have to set:

ParameterDefaultChanged toPurpose
Pn01E0000H0003HThe type of motor has to be selected
Pn40680025Emergency stop torque
Pn541655357000Max speed of the motor goes here
Pn543100010Speed detection level
Pn5441005Speed detection hysterisis
Pn63001Emergency stop execution delay time

These are the ones for tuning:

ParameterDefaultChanged toPurpose
Pn100400200Speed loop gain
Pn10120004000Speed loop integral time constant
Pn10310010Moment of inertia ratio