Critical information:



Programing the Drive

Load the Motor Config file.

You will need to load your particular motor file from PD.SIGMASD.01.zip.

image.png

Until you load the Motor config file, you may see the A.052 Alarm.

After loading the motor config file, then copy in the main drive parameters file.

The parameters file must be loaded AFTER the motor config file or else you may see the A.910 Alarm.

You will need to load your particular motor file from PD.SIGMASD.01.zip.

Additional Notes:
Parameter Default Changed to
PN800 100 10
PN802 100

10

PN82b.0 0

1

PN82c.0 0

1

ESP = the safety relay circuit to reduce the speed when stopping in estop circuit. 


Spindle Drive Example - Analog Pulse

Screen Shot 2022-09-04 at 9.03.16 PM.png


Motor Wiring Example:

IMG_3159.JPEG


Wiring Overview - Motor to Drive