Skip to main content

Repeatability Tests - Teco Drives

First, test for backlash. Section 2.4:

https://machmotion.com/documentation/Motion%20Controllers/Apollo%20III/Apollo-III-Manual-1000-Series.pdf

 

Move axis to a place where you can test to be sure if it returns exactly to that point or not (have a clear way to mark it for example) and where it has 10 or so inches of travel if possible. Zero out the DRO (the readout for the axis.  you can use DRO mode in the software in the upper right area so it doesn't change your fixture offsets).  Record the numbers displayed on the axis drive (the teco drives in the electrical enclosure).

 

Command motion (you can use the MDI box or load in a gcode file) to move axis down and back:

 

G00 G91

X10

X-10

 

Record the numbers displayed on the drive. (send us the before and after numbers). Did the DRO return to zero?  Did the machine make it back to the actual physical starting point?  Repeat test as needed to ensure it is repeatable or if not repeatable, run a few times to see if the "problem/offset" is repeatable.

 

 

Keywords: Position Error Testing