Hitachi VFD EtherCAT Parameter Settings

To set up the Hitachi VFD to be commanded by EtherCAT you will need to modify 2 parameters:

Parameter

Description Default Value Desired Value

AA101

Main Speed Source_M 1 (Term.[Ai1]) 9 (Option-1)
AA111 Run-cmd. Source_M1 0 (Term.[FW]/[RV]) 4 (Option-1)

 

If there is a delayed safety relay (knob or switches on the front of the safety relay), you will need to set up the following:
(BOM Example: image-1640187980182.png)image-1640187974688.png

 
  • CA-03: 31 (Sets S3 input to fast stop)
  • CA-23: 1 (Sets S3 input to Normally Closed)
  • AC-126: 4 (Or to your deceleration time)

You can also modify the fan settings with this parameter.

Parameter

Description Default Value Desired Value

bA-70

Cooling fan control 0 (Always on) 2 (Temperature controlled)

The RapidPath plugin controls (writes to) some parameters for operation. If you change the value of any of them, your change will be overwritten.

Parameter
CC-01
CC-02
CC-06
CC-07
This can be done automatically via Mach.

Go to Configure | Plugins | RapidPath - MachMotion:

image-1654551631993.png

Select the Other Devices tab, Click on the Hitachi VFD in the dropdown on the left and then select the Device Parameters at the bottom of the page:

image-1654551587280.png

From here you can click the Load from File button. Navigate to the Plugins/Dependencies/RapidPath/DriveConfig/Hitachi_VFD directory and select the file: Hitachi_Install_EtherCAT_I_O_device.drvprm.

image-1654551977607.png

Once it has loaded the parameter values, those which were updated, will be highlighted in green:

image-1654552327546.png

Click Write Changes button to save the updates to the drive.

You will need to recycle the drive for the change to the fan to take immediate effect.