VFDs

Yaskawa VFD

GA500

EtherCAT Setup

  • :3 :3 :1 :0 :0 :1 (forthisparameter)
  • O1-03: 1 (
  • than16161)

    For a A1000 or a GA500 or a GA800, also update the following parameters:

    :1 (
    ParameterValueDescription
    B1-01 3 EtherCAT
  • setup - Specific setting
  • B1-02 3 EtherCAT
  • setup - Specific setting
  • B1-08 1 EtherCAT
  • setup - Specific setting
  • F6-01 0 Factory
  • setting or configuration
  • F6-03 0 Factory
  • setting or configuration
  • F6-14 1 Cannot be changed from the front panel. panel; Use Drive Wizard
    O1-03 2 Frequency Display Unit Selection,Selection onSet releaseto laterRPM
    H5-11 1 Comm ENTER command not required)
    required setting for A1000, GA500, or GA800 series

      Standard Setup

      Setup Load in Mach. 

      image.png

      Spindle Load Input Scale Max is calculated as follows:

      Spindle Load Input Scale Max = Rated VFD Current X (1/multiplier)

      The multiplier is based on the VFD model number:

      • 0.01 A units: B001 - B018, 2001 - 2042, 4001 - 4023
      • 0.1A units: 2056 - 2082, 4031 - 4060

      So a 2021 VFD has a .01 multiplier. Spindle Load Input Scale Max = 21 amps X (1/.01) = 2100. 

      image.png

      Also, for the machine to wait for the spindle to reach the desired speed, make sure to check the Wait on spindle to stabilize. 

      image.png