VFDs
Yaskawa VFD
GA500
EtherCAT Setup
-
Parameter Value Description B1-01 :3 3EtherCAT - setup - Specific setting
B1-02 :3 3EtherCAT - setup - Specific setting
B1-08 :1 1EtherCAT - setup - Specific setting
F6-01 :0 0Factory - setting or configuration
F6-03 :0 0Factory - setting or configuration
F6-14 :1 1 (Cannot be changed from the front panel.panel; Use Drive Wizardforthisparameter)O1-03 2 O1-03: 1 (Frequency Display Unit Selection,SelectiononSetreleasetolaterRPMthan16161)For a A1000 or a GA500 or a GA800, also update the following parameters:H5-11 :1 1 (Comm ENTER command not required)
required setting for A1000, GA500, or GA800 series
- 0.01 A units: B001 - B018, 2001 - 2042, 4001 - 4023
- 0.1A units: 2056 - 2082, 4031 - 4060
Standard Setup
Setup Load in Mach.
Spindle Load Input Scale Max is calculated as follows:
Spindle Load Input Scale Max = Rated VFD Current X (1/multiplier)
The multiplier is based on the VFD model number:
So a 2021 VFD has a .01 multiplier. Spindle Load Input Scale Max = 21 amps X (1/.01) = 2100.
Also, for the machine to wait for the spindle to reach the desired speed, make sure to check the Wait on spindle to stabilize.