Troubleshooting RapidPath
RapidPath
RapidPath: Unexpected Error (Exception raised in synchronous message handler) / Motion: no axis mapped
No drive/motor nodes found on the EtherCAT network!
Either of these errors indicates that there were no nodes on the EtherCAT network that RMP believes are an axis.
- Confirm that the network in started.
- Confirm that there are nodes on the network.
- Confirm that the nodes are axes (each should have at least one Axis object underneath it).
INtime
Node A will not start.
"INtime Distribution license: full license - invalid"
The only thing that usually prevents the INtime node from starting is being unlicensed.
Newer versions of RMP require that we use a USB hardlock for the INtime licensing scheme. This allows RMP to use the same unique identifier for licensing as the hardlock.
- Verify that the USB hardlock is present and has a driver.
- (Windows Device Manager) Look for "SafeNet USB SuperPro/UltraPro" under "USB Devices"
- See Troubleshooting USB Devices for more detailed troubleshooting steps.
- Verify that INtime is licensed.
- (INtime Configuration / License Manager)
- See Licensing INtime for more details.