Skip to main content

Laser Controller Settings

Keyence LK-G5001 Laser Controller

Keyence_LK_G5001_photo.jpg

TODO:
 * add mfg documentation and links

Hardware

The Keyence LK-G5001 is a laser controller that can handle as many as two "heads" (measurement lasers). It has two "outs" (measured values).

Lasers

This machine uses two LK-H507 lasers.

LK-H05xy.png

Software

Keyence ships a desktop application that can be used to configure the laser controller: LK Navigator 2. It should be installed as a Windows application.

Configuration

Safety Circuit

The device has a safety mechanism where pin 1 (REMOTE) must be wired to pin 0 (COM IN) on the 12-pin terminal block.

LKG5001_REMOTE.png

Device Access

We access this device via the Machine Network. The IP address we use for it is 192.168.208.70/24.

It's (factory) default IP address is 192.168.10.10/16.

If the device gets factory reset, you will not be able to connect to it without (temporarily) reconfiguring the Machine Network NIC in Windows first.

Head/Out Settings

Most of the settings for this device are saved in the controller.

    • We use the default program (Program 0).
    • Head0 -> Out0
      • Units: convert mm -> inches
    • Head1 -> Out1
      • Units: convert mm -> inches
Head/Out
Heada laser input
Outa measured value (output)

The default settings for the device have both outs using head1.Head0. We want each headout to haveuse itsa owndifferent out.head.

We also configured the scaling for each output so that the measurements were in inches. Scaling takes two "points," (native_units, xform_units). To convert from mm (native units) to inches, use these points (0,0) -> (25.4,1).

Head -> Out Configuration
Out0/Head0Out1/Head1
Units Configuration
Out0 ScalingOut1 Scaling