Laser Controller Settings

Keyence LK-G5001 Laser Controller

Keyence_LK_G5001_photo.jpg

Hardware

The Keyence LK-G5001 is a laser controller that can handle as many as two "heads" (measurement lasers). It has two "outs" (measured values).

Lasers

This machine uses two LK-H507 lasers.

LK-H05xy.png

Software

Keyence ships a desktop application that can be used to configure the laser controller: LK Navigator 2. It should be installed as a Windows application.

Configuration

Safety Circuit

The device has a safety mechanism where pin 1 (REMOTE) must be wired to pin 0 (COM IN) on the 12-pin terminal block.

LKG5001_REMOTE.png

Device Access

We access this device via the Machine Network. The IP address we use for it is 192.168.208.70/24.

It's (factory) default IP address is 192.168.10.10/16.

If the device gets factory reset, you will not be able to connect to it without (temporarily) reconfiguring the Machine Network NIC in Windows first.

Head/Out Settings

The default settings for the device have both outs using head1. We want each head to have its own out.