Skip to main content

SOURCE MachPro Spindle Warm Up

MachPro has the ability to setup a Spindle Warm Up procedure for machines.

To be able to configure this go to Control->Plugins->MachMotion and then search for Spindle Warm Up.

Below is an example screen for the Spindle Warm Up settings.

image.png


Parameter  Description
Spindle Warm Up Off Time Trigger in minutes
How long do want the spindle to be off before the spindle will need to do the Warm Up cycle
Spindle Warm UP Acknowledge Warm-Up Complete The operator will need to acknowledge that the warm up cycle completed
Spindle Warm Up Enabled Warm Up Cycle On or Off
Spindle Warm Up Idle Speed Speed the spindle will idle at after the warm up is complete. Some spindles will not go very slow and may idle at 1500 RPM
Spindle Warm Up Inter-Lock with Cycle Start Yes or No
Spindle Warm Up MDI GCode Before Warm UP Provides an MDI field to enter GCode that will run before the Warm Up cycle begins
Spindle War Up Max RPM Max (finishing) speed for the warm up cycle. This should be the Max RPM of the spindle. 
Spindle Warm Up Min RPM Minimum (starting) speed for the warm up cycle (see note below)
Spindle Warm Up Steps How many steps will it take to get the spindle up to Warmed Up status - from Minimum to Maximum RPM
Spindle Warm Up Time Per Step How long it will stay in each Spindle Warm Up Step

Specific values:

  1. Locate the manufacturer's warm up instructions. If none of your resources produces those instructions, then set 2 minutes at each step, and 6000 per step, ending 6000 below max spindle RPM.
  2. Calculate the correct parameters for your spindle
  3. For the Spindle Warm Up Min RPM, enter 1. It will start at the correct minimum RPM and do the steps and time as you specified.

If you need a max warm up RPM of 18000, and you need it to spend 2 minutes at 6000 and 12000 also, then set:

Max RPM 18000.0000
Min RPM 1.0000
Steps 3
Time per step
2.0000

18000/3 = 6000