MachPro Lathe Setup Manual
{{@2007#bkmrk--1}}
Introduction
Configure your motion controller including: axis calibration, homing, limits, and I/O
LatheSpindle settings
These are the settings for the most commonly used Lathe features.{{@2047}}
Pull downConfigure -> Control -> Settings tabClick the
button to flatten the full settings tree, then expand theSpindlesection
Gear shifter
Before configuring the gear shifter, you need to configure your gear ranges. Use this portion of the Spindle Calibration document for gear range configuration. Set MaxRPM values for each gear
The default settings will work for a lathe with a manual gear shifter.
You may use M-codes to run the gear change cycle during a job. M40 - M45 change ranges from 0 to 5. M40 P# can also be used where # is the gear range to use
Load
Connect your encoder to an analog input and map the Spindle Load Meter Register to that input
Orient
MachPro uses M19 to run the orient sequence.
The two primary ways to use it are in Manual or Automatic mode
For Manual mode, the default configuration will work without any changes
For Automatic mode configure:
Spindle Orient TypeAutoSpindle Orient StyleMacroSpindle Orient OutputSpindle Orient Input
You may change the other parameters according to what your system needs.
Sub Spindle
The minimum settings that need to be configured for the subspindle are:
Sub Spindle EnabledSub Spindle CW outputSub Spindle CCW outputSub Spindle Max RPM
Use M-codes to control the sub spindle
M013 CW startM104 CCW startM105 stop
Spindle Warm Up
{{@2023}}
Lube System Setup
{{@2046}}
{{@2016}}