MachPro Lathe Setup Manual
{{@2007#bkmrk--1}}
Introduction
Configure your motion controller including: axis calibration, homing, limits, and I/O
Lathe settings
These are the default settings for the most commonly used Lathe features.
- Pull down Configure -> Control -> Settings tab
- Click the
button to flatten the full settings tree, then expand the Spindle section
Brake
The spindle brake is enabled by default. This for a brake that will slow the spindle to stop, not a brake that will hold the spindle in a stopped position.
Gear shifter
Before configuring the gear shifter, you need to configure your gear ranges. Use this portion of the Spindle Calibration document for gear range configuration. Set MaxRPM values for each gear
The default settings will work for a lathe with a manual gear shifter.
You may use M-codes to run the gear change cycle during a job. M40 - M45 change ranges from 0 to 5. M40 P# can also be used where # is the gear range to use
Load
Connect your encoder to an analog input and map the Spindle Load Meter Register to that input
Orient
MachPro uses M19 to run the orient sequence.
The two primary ways to use it are in Manual or Automatic mode
For Manual mode, the default configuration will work without any changes
For Automatic mode configure:
- Spindle Orient Type Auto
- Spindle Orient Style Macro
- Spindle Orient Output
- Spindle Orient Input
You may change the other parameters according to what your system needs.
Sub Spindle
SubspindleThe minimum settings that need to be configured for the subspindle are:
- Sub Spindle Enabled
- Sub Spindle CW output
- Sub Spindle CCW output
- Sub Spindle Max RPM
Use M-codes to control the sub spindle
- M013 CW start
- M104 CCW start
- M105 stop
{{@2023}}
Lube System Setup
{{@2016}}




