When the X and Y on a machine are not round yet the units are correct and the axes are square, make sure to match the gains in the Teco drives.The servo drive parameters may be mismatched:
You may only need to change one of these, but this is the order of priority:
- Pn310 Position Loop Gain 1
- Sn211 Speed Loop Gain 1
- Sn212 Speed Loop Integration Time Constant 1
- Pn312 Position Loop Feed-Forward Gain
For example, find the value of the X Pn310, and set the Y Pn310 to the same value.