Hitachi WJ200 Mini Manual
Hitachi WJ200
Alarm Codes:
Programming
To be able to program the Hitachi VFD you will either need to change the parameters physically on the VFD or with the Hitachi ProDrive Next software.
- Software requirements: Mini USB Cable connected to the VFD and the computer that will be doing the programming.
Example parameters:
GoMech Parameter file attached.
Parameter |
Name |
Definition |
Default Value |
Units |
Change Value |
B037 |
Function code display |
Unlock All Parameters |
4 |
|
0 |
A001 |
Frequency Source |
Options for frequency command: Control = 1, ModBus = 3, Option card = 4, etc. |
2 |
Opt. |
1 |
A002 |
Run Command Source |
Options for run command source |
2 |
|
1 |
F002 |
Acceleration time (1) |
Standard default acceleration, range is 0.01 to 3600 sec. |
10 |
sec |
3 |
F003 |
Deceleration time (1) |
Standard default deceleration, range is 0.01 to 3600 sec. |
10 |
Sec |
3 |
A003 |
Base Frequency |
Settable from 30 Hz to the maximum frequency(A004) |
60 |
Hz |
300 |
A004 |
Maximum Frequency |
Settable from the base frequency to 400 Hz Settable from the 2nd base frequency to 400 Hz |
60 |
Hz |
300 |
A082 |
Motor Voltage |
200V class: 200 / 215 / 220 / 230 / 240 VAC |
200 |
volts |
220 |
b012 |
Level of electronic thermal |
Set a level between 20% and 100% for the rated inverter current. |
Rated Current |
A |
100% |
H004 |
Poles |
|
4 |
|
2 |
B083 |
Carrier frequency |
Sets the PWM carrier (internal switching frequency), range is 2.0 to 15.0 kHz |
2 |
kHz |
4 |
See attached manufacturers manual for more details.