Hitachi WJ200 Mini Manual

Hitachi WJ200
Alarm Codes:

image-1654091242782.47.19 AM.png

image-1654091255989.47.33 AM.png

image-1654091268943.47.46 AM.png

image-1654091286905.48.04 AM.png

image-1654091302269.48.20 AM.png


Programming

To be able to program the Hitachi VFD you will either need to change the parameters physically on the VFD or with the Hitachi ProDrive Next software. 

Hitachi Software Downloads

- Software requirements: Mini USB Cable connected to the VFD and the computer that will be doing the programming.

Example parameters:

image-1654090800168.39.56 AM.png



GoMech Parameter file attached. 


Parameter

Name

Definition

Default Value

Units

Change Value

B037

Function code display
restriction

Unlock All Parameters

4


0

A001

Frequency Source

Options for frequency command: Control = 1, ModBus = 3, Option card = 4, etc. 

2

Opt.

1

A002

Run Command Source

Options for run command source

2


1

F002

Acceleration time (1)


Standard default acceleration, range is 0.01 to 3600 sec.

10

sec

3

F003

Deceleration time (1)

Standard default deceleration, range is 0.01 to 3600 sec.


10

Sec

3

A003

Base Frequency

Settable from 30 Hz to the maximum frequency(A004)

60

Hz

300

A004

Maximum Frequency

Settable from the base frequency to 400 Hz Settable from the 2nd base frequency to 400 Hz

60

Hz

300

A082

Motor Voltage

200V class: 200 / 215 / 220 / 230 / 240 VAC
400V class: 380 / 400 / 415 / 440 / 460 / 480 VAC

200

volts

220

b012

Level of electronic thermal

Set a level between 20% and 100% for the rated inverter current.

Rated Current

A

100%

H004

Poles


4


2

B083

Carrier frequency

Sets the PWM carrier (internal switching frequency), range is 2.0 to 15.0 kHz

2

kHz

4


image-1654090956045.49.52 AM.png

See attached manufacturers manual for more details.