DeviceName:WJ200(Ver.3.x,3.xE),Type:ParameterSet,Version:2.3.28.1 F Group "Data ID","Data Name","Setting value","Current value","Unit","Default value","Range","Comment" "F001","Output frequency setting","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "F002","Acceleration time (1)","3.00","3.00","s","10.00","0.00 ... 3600.00" "F202","Acceleration time (1),2nd motor","10.00","10.00","s","10.00","0.00 ... 3600.00" "F003","Deceleration time (1)","3.00","3.00","s","10.00","0.00 ... 3600.00" "F203","Deceleration time (1),2nd motor","10.00","10.00","s","10.00","0.00 ... 3600.00" "F004","Keypad RUN key routing","00:(Forward)","00:(Forward)","","00:(Forward)","" A Group "Data ID","Data Name","Setting value","Current value","Unit","Default value","Range","Comment" "A001","Frequency source","01:(Control terminal)","01:(Control terminal)","","02:(Function F001 setting)","" "A201","Frequency source,2nd motor","02:(Function F001 setting)","02:(Function F001 setting)","","02:(Function F001 setting)","" "A002","Run command source","01:(Control terminal)","01:(Control terminal)","","02:(Run key on keypad, or digital operator)","" "A202","Run command source,2nd motor","02:(Run key on keypad, or digital operator)","02:(Run key on keypad, or digital operator)","","02:(Run key on keypad, or digital operator)","" "A003","Base frequency","300.0","300.0","Hz","60.0","30.0 ... 300.0" "A203","Base frequency, 2nd motor","60.0","60.0","Hz","60.0","30.0 ... 60.0" "A004","Maximum frequency","300.0","300.0","Hz","60.0","300.0 ... 400.0" "A204","Maximum frequency, 2nd motor","60.0","60.0","Hz","60.0","60.0 ... 400.0" "A005","[AT] selection","00:(Select between [O] and [OI] at [AT] (ON=OI, OFF=O))","00:(Select between [O] and [OI] at [AT] (ON=OI, OFF=O))","","00:(Select between [O] and [OI] at [AT] (ON=OI, OFF=O))","" "A011","[O] input active range start frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A012","[O] input active range end frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A013","[O] input active range start voltage","0","0","%","0","0 ... 100" "A014","[O] input active range end voltage","100","100","%","100","0 ... 100" "A015","[O] input start frequency enable","01:(Use 0Hz)","01:(Use 0Hz)","","01:(Use 0Hz)","" "A016","Analog input filter","8","8","","8","1 ... 30, 31" "A017","EzSQ selection","00:(disabling)","00:(disabling)","","00:(disabling)","" "A019","Multi-speed operation selection","00:(Binary operation (16 speeds selectable with 4 terminals))","00:(Binary operation (16 speeds selectable with 4 terminals))","","00:(Binary operation (16 speeds selectable with 4 terminals))","" "A020","Multi-speed freq. 0","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A220","Multi-speed freq. 0, 2nd motor","0.00","0.00","Hz","0.00","0.00, 0.50 ... 60.00" "A021","Multi-speed freq. 1","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A022","Multi-speed freq. 2","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A023","Multi-speed freq. 3","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A024","Multi-speed freq. 4","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A025","Multi-speed freq. 5","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A026","Multi-speed freq. 6","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A027","Multi-speed freq. 7","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A028","Multi-speed freq. 8","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A029","Multi-speed freq. 9","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A030","Multi-speed freq. 10","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A031","Multi-speed freq. 11","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A032","Multi-speed freq. 12","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A033","Multi-speed freq. 13","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A034","Multi-speed freq. 14","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A035","Multi-speed freq. 15","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A038","Jog frequency","6.00","6.00","Hz","6.00","0.50 ... 9.99" "A039","Jog stop mode","04:(Controlled deceleration (valid during run))","04:(Controlled deceleration (valid during run))","","04:(Controlled deceleration (valid during run))","" "A041","Torque boost select","00:(Manual torque boost)","00:(Manual torque boost)","","00:(Manual torque boost)","" "A241","Torque boost select, 2nd motor","00:(Manual torque boost)","00:(Manual torque boost)","","00:(Manual torque boost)","" "A042","Manual torque boost value","1.0","1.0","%","1.0","0.0 ... 20.0" "A242","Manual torque boost value, 2nd motor","1.0","1.0","%","1.0","0.0 ... 20.0" "A043","Manual torque boost frequency","5.0","5.0","%","5.0","0.0 ... 50.0" "A243","Manual torque boost frequency,2nd motor","5.0","5.0","%","5.0","0.0 ... 50.0" "A044","V/f characteristic curve","00:(Constant torque)","00:(Constant torque)","","00:(Constant torque)","" "A244","V/f characteristic curve,2nd motor","00:(Constant torque)","00:(Constant torque)","","00:(Constant torque)","" "A045","V/f gain","100","100","%","100","20 ... 100" "A245","V/f gain, 2nd motor","100","100","%","100","20 ... 100" "A046","Voltage compensation gain for automatic torque boost","100","100","","100","0 ... 255" "A246","Voltage compensation gain for automatic torque boost, 2nd motor","100","100","","100","0 ... 255" "A047","Slip compensation gain for automatic torque boost","100","100","","100","0 ... 255" "A247","Slip compensation gain for automatic torque boost, 2nd motor","100","100","","100","0 ... 255" "A051","DC braking enable","00:(Disable)","00:(Disable)","","00:(Disable)","" "A052","DC braking frequency","0.50","0.50","Hz","0.50","0.00 ... 60.00" "A053","DC braking wait time","0.0","0.0","s","0.0","0.0 ... 5.0" "A054","DC braking force for deceleration","50","50","%","50","0 ... 100" "A055","DC braking time for deceleration","0.5","0.5","s","0.5","0.0 ... 60.0" "A056","DC braking / edge or level detection for [DB] input","01:(Level detection)","01:(Level detection)","","01:(Level detection)","" "A057","DC braking force at start","0","0","%","0","0 ... 100" "A058","DC braking time at start","0.0","0.0","s","0.0","0.0 ... 60.0" "A059","Carrier frequency during DC braking","5.0","5.0","kHz","5.0","2.0 ... 15.0" "A061","Frequency upper limit","0.00","0.00","Hz","0.00","0.00 ... 300.00" "A261","Frequency upper limit,2nd motor","0.00","0.00","Hz","0.00","0.00 ... 60.00" "A062","Frequency lower limit","0.00","0.00","Hz","0.00","0.00, 0.50 ... 300.00" "A262","Frequency lower limit,2nd motor","0.00","0.00","Hz","0.00","0.00, 0.50 ... 60.00" "A063","Jump freq. (center) 1","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A064","Jump freq. width (hysteresis) 1","0.50","0.50","Hz","0.50","0.00 ... 10.00" "A065","Jump freq. (center) 2","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A066","Jump freq. width (hysteresis) 2","0.50","0.50","Hz","0.50","0.00 ... 10.00" "A067","Jump freq. (center) 3","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A068","Jump freq. width (hysteresis) 3","0.50","0.50","Hz","0.50","0.00 ... 10.00" "A069","Acceleration hold frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A070","Acceleration hold time","0.0","0.0","s","0.0","0.0 ... 60.0" "A071","PID enable","00:(PID Disable)","00:(PID Disable)","","00:(PID Disable)","" "A072","PID proportional gain","1.00","1.00","","1.00","0.00 ... 25.00" "A073","PID integral time constant","1.0","1.0","s","1.0","0.0 ... 3600.0" "A074","PID derivative time constant","0.00","0.00","s","0.00","0.00 ... 100.00" "A075","PV scale conversion","1.00","1.00","","1.00","0.01 ... 99.99" "A076","PV source","00:([OI] terminal (current in))","00:([OI] terminal (current in))","","00:([OI] terminal (current in))","" "A077","Reverse PID action","00:(PID input = SP-PV)","00:(PID input = SP-PV)","","00:(PID input = SP-PV)","" "A078","PID output limit","0.0","0.0","%","0.0","0.0 ... 100.0" "A079","PID feed forward selection","00:(Disabled)","00:(Disabled)","","00:(Disabled)","" "A081","AVR function select","02:(AVR enabled except during deceleration)","02:(AVR enabled except during deceleration)","","02:(AVR enabled except during deceleration)","" "A281","AVR function select,2nd motor","02:(AVR enabled except during deceleration)","02:(AVR enabled except during deceleration)","","02:(AVR enabled except during deceleration)","" "A082","AVR voltage select","00:(200)","00:(200)","V","00:(200)","" "A282","AVR voltage select,2nd motor","00:(200)","00:(200)","V","00:(200)","" "A083","AVR filter time constant","0.300","0.300","s","0.300","0.000 ... 10.000" "A084","AVR deceleration gain","100","100","%","100","50 ... 200" "A085","Energy-saving operation mode","00:(Normal operation)","00:(Normal operation)","","00:(Normal operation)","" "A086","Energy-saving mode tuning","50.0","50.0","%","50.0","0.0 ... 100.0" "A092","Acceleration time (2)","10.00","10.00","s","10.00","0.00 ... 3600.00" "A292","Acceleration time (2),2nd motor","10.00","10.00","s","10.00","0.00 ... 3600.00" "A093","Deceleration time (2)","10.00","10.00","s","10.00","0.00 ... 3600.00" "A293","Deceleration time (2),2nd motor","10.00","10.00","s","10.00","0.00 ... 3600.00" "A094","Select method to switch to Acc2/Dec2 profile","00:(2CH input from terminal)","00:(2CH input from terminal)","","00:(2CH input from terminal)","" "A294","Select method to switch to Acc2/Dec2 profile, 2nd motor","00:(2CH input from terminal)","00:(2CH input from terminal)","","00:(2CH input from terminal)","" "A095","Acc1 to Acc2 frequency transition point","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A295","Acc1 to Acc2 frequency transition point, 2nd motor","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A096","Dec1 to Dec2 frequency transition point","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A296","Dec1 to Dec2 frequency transition point, 2nd motor","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A097","Acceleration curve selection","01:(S-curve)","01:(S-curve)","","01:(S-curve)","" "A098","Deceleration curve selection","01:(S-curve)","01:(S-curve)","","01:(S-curve)","" "A101","[OI] input active range start frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A102","[OI] input active range end frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A103","[OI] input active range start current","20","20","%","20","0 ... 100" "A104","[OI] input active range end current","100","100","%","100","20 ... 100" "A105","[OI] input start frequency select","00:(Use offset (A101 value))","00:(Use offset (A101 value))","","00:(Use offset (A101 value))","" "A131","Acceleration curve constant","2","2","","2","1 ... 10" "A132","Deceleration curve constant","2","2","","2","1 ... 10" "A141","A input select for calculate function","02:(Terminal [O] input)","02:(Terminal [O] input)","","02:(Terminal [O] input)","" "A142","B input select for calculate function","03:(Terminal [OI] input)","03:(Terminal [OI] input)","","03:(Terminal [OI] input)","" "A143","Calculation symbol","00:(ADD (A input + B input))","00:(ADD (A input + B input))","","00:(ADD (A input + B input))","" "A145","ADD frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A146","ADD direction select","00:(Plus (adds A145 value to the output frequency setting))","00:(Plus (adds A145 value to the output frequency setting))","","00:(Plus (adds A145 value to the output frequency setting))","" "A150","Curvature of EL-S-curve at the start of acceleration","10","10","%","10","0 ... 50" "A151","Curvature of EL-S-curve at the end of acceleration","10","10","%","10","0 ... 50" "A152","Curvature of EL-S-curve at the start of deceleration","10","10","%","10","0 ... 50" "A153","Curvature of EL-S-curve at the end of deceleration","10","10","%","10","0 ... 50" "A154","Deceleration hold frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A155","Deceleration hold time","0.0","0.0","s","0.0","0.0 ... 60.0" "A156","PID sleep function action threshold","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A157","PID sleep function action delay time","0.0","0.0","s","0.0","0.0 ... 25.5" "A161","[VR] input active range start frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A162","[VR] input active range end frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "A163","[VR] input active range start","0","0","%","0","0 ... 100" "A164","[VR] input active range end","100","100","%","100","0 ... 100" "A165","[VR] input start frequency select","01:(Use 0Hz)","01:(Use 0Hz)","","01:(Use 0Hz)","" B Group "Data ID","Data Name","Setting value","Current value","Unit","Default value","Range","Comment" "b001","Restart mode on power failure / under-voltage trip","00:(Alarm output after trip, no automatic restart)","00:(Alarm output after trip, no automatic restart)","","00:(Alarm output after trip, no automatic restart)","" "b002","Allowable under-voltage power failure time","1.0","1.0","s","1.0","0.3 ... 25.0" "b003","Retry wait time before motor restart","1.0","1.0","s","1.0","0.3 ... 100.0" "b004","Instantaneous power failure / under-voltage trip alarm enable","00:(Disable)","00:(Disable)","","00:(Disable)","" "b005","Number of restarts on power failure / under-voltage trip events","00:(Restart 16 times)","00:(Restart 16 times)","","00:(Restart 16 times)","" "b007","Restart frequency threshold","0.00","0.00","Hz","0.00","0.00 ... 400.00" "b008","Restart mode on over voltage / over current trip","00:(Alarm output after trip, no automatic restart)","00:(Alarm output after trip, no automatic restart)","","00:(Alarm output after trip, no automatic restart)","" "b010","Number of retry on over voltage / over current trip","3","3","times","3","1 ... 3" "b011","Retry wait time on over voltage / over current trip","1.0","1.0","s","1.0","0.3 ... 100.0" "b012","Level of electronic thermal","100.0","100.0","%","100.0","20.0 ... 100.0" "b212","Level of electronic thermal, 2nd motor","100.0","100.0","%","100.0","20.0 ... 100.0" "b013","Electronic thermal characteristic","01:(Constant torque)","01:(Constant torque)","","01:(Constant torque)","" "b213","Electronic thermal characteristic, 2nd motor","01:(Constant torque)","01:(Constant torque)","","01:(Constant torque)","" "b015","Free setting, electronic thermal frequency (1)","0","0","Hz","0","0" "b016","Free setting, electronic thermal current (1)","0.0","0.0","%","0.0","0.0 ... 100.0" "b017","Free setting, electronic thermal frequency (2)","0","0","Hz","0","0" "b018","Free setting, electronic thermal current (2)","0.0","0.0","%","0.0","0.0 ... 100.0" "b019","Free setting, electronic thermal frequency (3)","0","0","Hz","0","0 ... 400" "b020","Free setting, electronic thermal current (3)","0.0","0.0","%","0.0","0.0 ... 100.0" "b021","Overload restriction operation mode","01:(Enabled for acceleration and constant speed)","01:(Enabled for acceleration and constant speed)","","01:(Enabled for acceleration and constant speed)","" "b221","Overload restriction operation mode, 2nd motor","01:(Enabled for acceleration and constant speed)","01:(Enabled for acceleration and constant speed)","","01:(Enabled for acceleration and constant speed)","" "b022","Overload restriction level","150.0","150.0","%","150.0","20.0 ... 200.0" "b222","Overload restriction level, 2nd motor","150.0","150.0","%","150.0","20.0 ... 200.0" "b023","Deceleration rate at overload restriction","1.0","1.0","s","1.0","0.1 ... 3000.0" "b223","Deceleration rate at overload restriction, 2nd motor","1.0","1.0","s","1.0","0.1 ... 3000.0" "b024","Overload restriction operation mode 2","01:(Enabled for acceleration and constant speed)","01:(Enabled for acceleration and constant speed)","","01:(Enabled for acceleration and constant speed)","" "b025","Overload restriction level 2","150.0","150.0","%","150.0","20.0 ... 200.0" "b026","Deceleration rate 2 at overload restriction","1.0","1.0","s","1.0","0.1 ... 3000.0" "b027","OC suppression selection","01:(Enabled - Without voltage reduction)","01:(Enabled - Without voltage reduction)","","01:(Enabled - Without voltage reduction)","" "b028","Current level of active freq.matching","100.0","100.0","%","100.0","20.0 ... 200.0" "b029","Deceleration rate of active freq. matching","0.5","0.5","s","0.5","0.1 ... 3000.0" "b030","Start freq. of active freq. matching","00:(freq at previous shutoff)","00:(freq at previous shutoff)","","00:(freq at previous shutoff)","" "b031","Software lock mode selection","01:(all parameters except B031 and output frequency F001 are locked when [SFT] terminal is ON)","01:(all parameters except B031 and output frequency F001 are locked when [SFT] terminal is ON)","","01:(all parameters except B031 and output frequency F001 are locked when [SFT] terminal is ON)","" "b033","Motor cable length parameter","10","10","","10","5 ... 20" "b034","Run/power ON warning time","0","0","hr","0","0 ... 655350" "b035","Rotation direction restriction","00:(No restriction)","00:(No restriction)","","00:(No restriction)","" "b036","Reduced voltage start selection","2","2","","2","0 ... 255" "b037","Function code display restriction","04:(Basic display)","04:(Basic display)","","04:(Basic display)","" "b038","Initial display selection","001:(d001)","001:(d001)","","001:(d001)","" "b039","Automatic user parameter registration","00:(Disable)","00:(Disable)","","00:(Disable)","" "b040","Torque limit selection","00:(Quadrant-specific setting mode)","00:(Quadrant-specific setting mode)","","00:(Quadrant-specific setting mode)","" "b041","Torque limit 1 (fwd/power)","200","200","%","200","0 ... 200, 255" "b042","Torque limit 2 (rev/regen.)","200","200","%","200","0 ... 200, 255" "b043","Torque limit 3 (rev/power)","200","200","%","200","0 ... 200, 255" "b044","Torque limit 4 (fwd/regen.)","200","200","%","200","0 ... 200, 255" "b045","Torque LAD STOP selection","00:(Disable)","00:(Disable)","","00:(Disable)","" "b046","Reverse run protection","01:(Reverse rotation is protected)","01:(Reverse rotation is protected)","","01:(Reverse rotation is protected)","" "b049","Dual Rating Selection","00:(CT mode)","00:(CT mode)","","00:(CT mode)","" "b050","Controlled deceleration on power loss","00:(Trips)","00:(Trips)","","00:(Trips)","" "b051","DC bus voltage trigger level of ctrl. decel.","220.0","220.0","V","220.0","0.0 ... 1000.0" "b052","Over-voltage threshold of ctrl. decel.","360.0","360.0","V","360.0","0.0 ... 1000.0" "b053","Deceleration time of ctrl. decel.","1.00","1.00","s","1.00","0.01 ... 3600.00" "b054","Initial freq. drop of ctrl. decel.","0.00","0.00","Hz","0.00","0.00 ... 10.00" "b060","Maximum-limit level of window comparators O","100","100","%","100","0 ... 100" "b061","Minimum-limit level of window comparators O","0","0","%","0","0 ... 100" "b062","Hysteresis width of window comparators O","0","0","%","0","0 ... 50" "b063","Maximum-limit level of window comparators OI","100","100","%","100","0 ... 100" "b064","Minimum-limit level of window comparators OI","0","0","%","0","0 ... 100" "b065","Hysteresis width of window comparator OI","0","0","%","0","0 ... 50" "b070","Operation level at O disconnection","255","255","%","255","0 ... 100, 255" "b071","Operation level at OI disconnection","255","255","%","255","0 ... 100, 255" "b075","Ambient temperature","40","40","C","40","-10 ... 50" "b078","Watt-hour clearance","00:(OFF)","00:(OFF)","","00:(OFF)","" "b079","Watt-hour display gain","1","1","","1","1 ... 1000" "b082","Start frequency","0.50","0.50","Hz","0.50","0.01 ... 9.99" "b083","Carrier frequency","2.0","2.0","kHz","2.0","2.0 ... 15.0" "b084","Initialization mode (parameters or trip history)","00:(Initialization disabled)","00:(Initialization disabled)","","00:(Initialization disabled)","" "b085","Country for initialization","00:(Japan)","00:(Japan)","","00:(Japan)","" "b086","Frequency scaling conversion factor","1.00","1.00","","1.00","0.01 ... 99.99" "b087","STOP key enable","00:(Enabled)","00:(Enabled)","","00:(Enabled)","" "b088","Restart mode after FRS","00:(Restart from 0Hz)","00:(Restart from 0Hz)","","00:(Restart from 0Hz)","" "b089","Automatic carrier frequency reduction","01:(Enabled, depending on the output current)","01:(Enabled, depending on the output current)","","01:(Enabled, depending on the output current)","" "b090","Dynamic braking usage ratio","0.0","0.0","%","0.0","0.0 ... 10.0" "b091","Stop mode selection","00:(DEC (decelerate to stop))","00:(DEC (decelerate to stop))","","00:(DEC (decelerate to stop))","" "b092","Cooling fan control","01:(Fan is ON during run, OFF during stop (5 minute delay from ON to OFF))","01:(Fan is ON during run, OFF during stop (5 minute delay from ON to OFF))","","01:(Fan is ON during run, OFF during stop (5 minute delay from ON to OFF))","" "b093","Clear elapsed time of cooling fan","00:(Count)","00:(Count)","","00:(Count)","" "b094","Initialization target data","00:(All parameters)","00:(All parameters)","","00:(All parameters)","" "b095","Dynamic braking control (BRD) selection","01:(Enable during run only)","01:(Enable during run only)","","01:(Enable during run only)","" "b096","BRD activation level","360","360","V","360","330 ... 390" "b097","BRD resistor value","35.0","35.0","Ohm","35.0","35.0 ... 600.0" "b100","Free-setting V/F freq. (1)","0","0","Hz","0","0" "b101","Free-setting V/F volt. (1)","0.0","0.0","V","0.0","0.0 ... 800.0" "b102","Free-setting V/F freq. (2)","0","0","Hz","0","0" "b103","Free-setting V/F volt. (2)","0.0","0.0","V","0.0","0.0 ... 800.0" "b104","Free-setting V/F freq. (3)","0","0","Hz","0","0" "b105","Free-setting V/F volt. (3)","0.0","0.0","V","0.0","0.0 ... 800.0" "b106","Free-setting V/F freq. (4)","0","0","Hz","0","0" "b107","Free-setting V/F volt. (4)","0.0","0.0","V","0.0","0.0 ... 800.0" "b108","Free-setting V/F freq. (5)","0","0","Hz","0","0" "b109","Free-setting V/F volt. (5)","0.0","0.0","V","0.0","0.0 ... 800.0" "b110","Free-setting V/F freq. (6)","0","0","Hz","0","0" "b111","Free-setting V/F volt. (6)","0.0","0.0","V","0.0","0.0 ... 800.0" "b112","Free-setting V/F freq. (7)","0","0","Hz","0","0 ... 400" "b113","Free-setting V/F volt. (7)","0.0","0.0","V","0.0","0.0 ... 800.0" "b120","Brake control enable","00:(Disable)","00:(Disable)","","00:(Disable)","" "b121","Brake Wait Time for Release","0.00","0.00","s","0.00","0.00 ... 5.00" "b122","Brake Wait Time for Acceleration","0.00","0.00","s","0.00","0.00 ... 5.00" "b123","Brake Wait Time for Stopping","0.00","0.00","s","0.00","0.00 ... 5.00" "b124","Brake Wait Time for Confirmation","0.00","0.00","s","0.00","0.00 ... 5.00" "b125","Brake release freq.","0.00","0.00","Hz","0.00","0.00 ... 400.00" "b126","Brake release current","100.0","100.0","%","100.0","0.0 ... 200.0" "b127","Braking frequency","0.00","0.00","Hz","0.00","0.00 ... 400.00" "b130","Deceleration overvoltage suppression enable","00:(Disabled)","00:(Disabled)","","00:(Disabled)","" "b131","Decel. overvolt. suppress level","380","380","V","380","330 ... 395" "b132","Decel. overvolt. suppress const.","1.00","1.00","s","1.00","0.10 ... 30.00" "b133","Decel. overvolt. suppress proportional gain","0.20","0.20","times","0.20","0.00 ... 5.00" "b134","Decel. overvolt. suppress integral time","1.0","1.0","s","1.0","0.0 ... 150.0" "b145","GS input mode select","00:(No trip (Hardware shutoff only))","00:(No trip (Hardware shutoff only))","","00:(No trip (Hardware shutoff only))","" "b146","Delay time of release operation","0.00","0.00","s","0.00","0.00 ... 2.00" "b147","Special monitor display cancellation","00:(Cancellation of special display is invalid)","00:(Cancellation of special display is invalid)","","00:(Cancellation of special display is invalid)","" "b148","Special monitor display re-display time","30","30","","30","1 ... 30" "b150","Display ex.operator connected","d001","d001","","d001","" "b160","1st parameter of Dual Monitor","d001","d001","","d001","" "b161","2nd parameter of Dual Monitor","d002","d002","","d002","" "b163","Freq. set in monitoring","00:(Freq. set disabled)","00:(Freq. set disabled)","","00:(Freq. set disabled)","" "b164","Automatic return to the initial display","00:(Disable)","00:(Disable)","","00:(Disable)","" "b165","Ex. operator com. loss action","02:(Ignore)","02:(Ignore)","","02:(Ignore)","" "b166","Data read/write selection","00:(R/W enable)","00:(R/W enable)","","00:(R/W enable)","" "b171","Inverter mode selection","00:(Disabling)","00:(Disabling)","","00:(Disabling)","" "b180","Initialization trigger","00:(Initialization disable)","00:(Initialization disable)","","00:(Initialization disable)","" "b910","Electronic thermal subtraction function selection","00:(OFF)","00:(OFF)","","00:(OFF)","" "b911","Thermal subtraction time","600.00","600.00","s","600.00","0.10 ... 100000.00" "b912","Thermal subtraction time constant","120.00","120.00","s","120.00","0.10 ... 100000.00" "b913","Thermal accumulation gain","100.0","100.0","%","100.0","0.0 ... 200.0" C Group "Data ID","Data Name","Setting value","Current value","Unit","Default value","Range","Comment" "C001","Input [1] function","00:(FW:FORWARD Run/Stop)","00:(FW:FORWARD Run/Stop)","","00:(FW:FORWARD Run/Stop)","" "C002","Input [2] function","01:(RV:Reverse Run/Stop)","01:(RV:Reverse Run/Stop)","","01:(RV:Reverse Run/Stop)","" "C003","Input [3] function","02:(CF1:Multi-speed Select,Bit 0 (LSB))","02:(CF1:Multi-speed Select,Bit 0 (LSB))","","02:(CF1:Multi-speed Select,Bit 0 (LSB))","" "C004","Input [4] function","03:(CF2:Multi-speed Select,Bit 1)","03:(CF2:Multi-speed Select,Bit 1)","","03:(CF2:Multi-speed Select,Bit 1)","" "C005","Input [5] function","09:(2CH:2-stage Acceleration and Deceleration)","09:(2CH:2-stage Acceleration and Deceleration)","","09:(2CH:2-stage Acceleration and Deceleration)","" "C006","Input [6] function","18:(RS:Reset Inverter)","18:(RS:Reset Inverter)","","18:(RS:Reset Inverter)","" "C007","Input [7] function","13:(USP:Unattended Start Protection)","13:(USP:Unattended Start Protection)","","13:(USP:Unattended Start Protection)","" "C011","Input [1] active state","00:normally open [NO]","00:normally open [NO]","","00:normally open [NO]","" "C012","Input [2] active state","00:normally open [NO]","00:normally open [NO]","","00:normally open [NO]","" "C013","Input [3] active state","00:normally open [NO]","00:normally open [NO]","","00:normally open [NO]","" "C014","Input [4] active state","00:normally open [NO]","00:normally open [NO]","","00:normally open [NO]","" "C015","Input [5] active state","00:normally open [NO]","00:normally open [NO]","","00:normally open [NO]","" "C016","Input [6] active state","00:normally open [NO]","00:normally open [NO]","","00:normally open [NO]","" "C017","Input [7] active state","00:normally open [NO]","00:normally open [NO]","","00:normally open [NO]","" "C021","Output [11] function","01:(FA1:Frequency Arrival Type 1-Constant Speed)","01:(FA1:Frequency Arrival Type 1-Constant Speed)","","01:(FA1:Frequency Arrival Type 1-Constant Speed)","" "C022","Output [12] function","00:(RUN:Run Signal)","00:(RUN:Run Signal)","","00:(RUN:Run Signal)","" "C026","Alarm relay function","05:(AL:Alarm Signal)","05:(AL:Alarm Signal)","","05:(AL:Alarm Signal)","" "C027","[EO] terminal selection(Pulse/PWM output)","07:(LAD frequency (PWM))","07:(LAD frequency (PWM))","","07:(LAD frequency (PWM))","" "C028","[AM] terminal selection(Analog voltage output 0...10V)","07:(LAD frequency)","07:(LAD frequency)","","07:(LAD frequency)","" "C030","Digital current monitor reference value","100.0","100.0","%","100.0","20.0 ... 200.0" "C031","Output [11] active state","00:normally open [NO]","00:normally open [NO]","","00:normally open [NO]","" "C032","Output [12] active state","00:normally open [NO]","00:normally open [NO]","","00:normally open [NO]","" "C036","Alarm relay active state","01:normally closed [NC]","01:normally closed [NC]","","01:normally closed [NC]","" "C038","Output mode of low current detection","01:(During constant speed only)","01:(During constant speed only)","","01:(During constant speed only)","" "C039","Low current detection level","100.0","100.0","%","100.0","0.0 ... 200.0" "C040","Output mode of overload warning","01:(During constant speed only)","01:(During constant speed only)","","01:(During constant speed only)","" "C041","Overload warning level","115.0","115.0","%","115.0","0.0 ... 200.0" "C241","Overload warning level, 2nd motor","115.0","115.0","%","115.0","0.0 ... 200.0" "C042","Frequency arrival setting for acceleration","0.00","0.00","Hz","0.00","0.00 ... 400.00" "C043","Frequency arrival setting for deceleration","0.00","0.00","Hz","0.00","0.00 ... 400.00" "C044","PID deviation level","3.0","3.0","%","3.0","0.0 ... 100.0" "C045","Frequency arrival setting 2 for acceleration","0.00","0.00","Hz","0.00","0.00 ... 400.00" "C046","Frequency arrival setting 2 for deceleration","0.00","0.00","Hz","0.00","0.00 ... 400.00" "C047","Pulse train input/output scale conversion","1.00","1.00","","1.00","0.01 ... 99.99" "C052","PID FBV output high limit","100.0","100.0","%","100.0","0.0 ... 100.0" "C053","PID FBV output low limit","0.0","0.0","%","0.0","0.0 ... 100.0" "C054","Over-torque/under-torque selection","00:(Over-torque)","00:(Over-torque)","","00:(Over-torque)","" "C055","Over/under-torque level(Forward powering mode)","100","100","%","100","0 ... 200" "C056","Over/under-torque level(Reverse regen. mode)","100","100","%","100","0 ... 200" "C057","Over/under-torque level(Reverse powering mode)","100","100","%","100","0 ... 200" "C058","Over/under-torque level(Forward regen. mode)","100","100","%","100","0 ... 200" "C059","Signal output mode of Over/under-torque","01:(During constant speed only)","01:(During constant speed only)","","01:(During constant speed only)","" "C061","Electronic thermal warning level","90","90","%","90","0 ... 100" "C063","Zero speed detection level","0.00","0.00","Hz","0.00","0.00 ... 100.00" "C064","Heat sink overheat warning","100","100","C","100","0 ... 110" "C071","Communication speed","05:(9600bps)","05:(9600bps)","","05:(9600bps)","" "C072","Modbus address","1","1","","1","1 ... 247" "C074","Communication parity","00:(No parity)","00:(No parity)","","00:(No parity)","" "C075","Communication stop bit","01:(1bit)","01:(1bit)","","01:(1bit)","" "C076","Communication error select","02:(Disable)","02:(Disable)","","02:(Disable)","" "C077","Communication error time-out","0.00","0.00","s","0.00","0.00 ... 99.99" "C078","Communication wait time","0","0","ms","0","0 ... 1000" "C081","O input span calibration","100.0","100.0","%","100.0","0.0 ... 200.0" "C082","OI input span calibration","100.0","100.0","%","100.0","0.0 ... 200.0" "C085","Thermistor input (PTC) span calibration","100.0","100.0","%","100.0","0.0 ... 200.0" "C091","Debug mode enable","00:(Disable)","00:(Disable)","","00:(Disable)","" "C096","Communication selection","00:(Modbus-RTU)","00:(Modbus-RTU)","","00:(Modbus-RTU)","" "C098","EzCOM start adr. of master","1","1","","1","1 ... 8" "C099","EzCOM end adr. of master","1","1","","1","1 ... 8" "C100","EzCOM starting trigger","00:(Input terminal(485RUN))","00:(Input terminal(485RUN))","","00:(Input terminal(485RUN))","" "C101","Up/Down memory mode selection","00:(Clear last frequency (return to default frequency F001))","00:(Clear last frequency (return to default frequency F001))","","00:(Clear last frequency (return to default frequency F001))","" "C102","Reset selection","00:(Cancel trip state at input signal ON transition, stops inverter if in Run Mode)","00:(Cancel trip state at input signal ON transition, stops inverter if in Run Mode)","","00:(Cancel trip state at input signal ON transition, stops inverter if in Run Mode)","" "C103","Restart mode after reset","00:(Start with 0 Hz)","00:(Start with 0 Hz)","","00:(Start with 0 Hz)","" "C104","UP/DWN clear mode","00:(0Hz)","00:(0Hz)","","00:(0Hz)","" "C105","EO gain adjustment","100","100","%","100","50 ... 200" "C106","AM gain adjustment","100","100","%","100","50 ... 200" "C109","AM bias adjustment","0","0","%","0","0 ... 100" "C111","Overload warning level 2","115.0","115.0","%","115.0","0.0 ... 200.0" "C130","Output [11] on delay","0.0","0.0","s","0.0","0.0 ... 100.0" "C131","Output [11] off delay","0.0","0.0","s","0.0","0.0 ... 100.0" "C132","Output [12] on delay","0.0","0.0","s","0.0","0.0 ... 100.0" "C133","Output [12] off delay","0.0","0.0","s","0.0","0.0 ... 100.0" "C140","Relay output on delay","0.0","0.0","s","0.0","0.0 ... 100.0" "C141","Relay output off delay","0.0","0.0","s","0.0","0.0 ... 100.0" "C142","Logic output 1 operand A","00:(RUN:Run Signal)","00:(RUN:Run Signal)","","00:(RUN:Run Signal)","" "C143","Logic output 1 operand B","00:(RUN:Run Signal)","00:(RUN:Run Signal)","","00:(RUN:Run Signal)","" "C144","Logic output 1 operator","00:([LOG] = A AND B)","00:([LOG] = A AND B)","","00:([LOG] = A AND B)","" "C145","Logic output 2 operand A","00:(RUN:Run Signal)","00:(RUN:Run Signal)","","00:(RUN:Run Signal)","" "C146","Logic output 2 operand B","00:(RUN:Run Signal)","00:(RUN:Run Signal)","","00:(RUN:Run Signal)","" "C147","Logic output 2 operator","00:([LOG] = A AND B)","00:([LOG] = A AND B)","","00:([LOG] = A AND B)","" "C148","Logic output 3 operand A","00:(RUN:Run Signal)","00:(RUN:Run Signal)","","00:(RUN:Run Signal)","" "C149","Logic output 3 operand B","00:(RUN:Run Signal)","00:(RUN:Run Signal)","","00:(RUN:Run Signal)","" "C150","Logic output 3 operator","00:([LOG] = A AND B)","00:([LOG] = A AND B)","","00:([LOG] = A AND B)","" "C160","Input [1] response time","1","1","","1","0 ... 200" "C161","Input [2] response time","1","1","","1","0 ... 200" "C162","Input [3] response time","1","1","","1","0 ... 200" "C163","Input [4] response time","1","1","","1","0 ... 200" "C164","Input [5] response time","1","1","","1","0 ... 200" "C165","Input [6] response time","1","1","","1","0 ... 200" "C166","Input [7] response time","1","1","","1","0 ... 200" "C169","Multistage speed/position determination time","0","0","","0","0 ... 200" "C900","IRDY action selection","01:(After Step3(Ver. 3.0))","01:(After Step3(Ver. 3.0))","","01:(After Step3(Ver. 3.0))","" "C901","Judge cycle select of overload warning","00:(40ms cycle)","00:(40ms cycle)","","00:(40ms cycle)","" "C902","Time const. for overload warning judge","0","0","ms","0","0 ... 9999" "C903","Hysteresis for overload warning judge","10.00","10.00","%","10.00","0.00 ... 50.00" H Group "Data ID","Data Name","Setting value","Current value","Unit","Default value","Range","Comment" "H001","Auto-tuning selection","00:(Disabled)","00:(Disabled)","","00:(Disabled)","" "H002","Motor constant selection","00:(Hitachi standard motor )","00:(Hitachi standard motor )","","00:(Hitachi standard motor )","" "H202","Motor constant selection, 2nd motor","00:(Hitachi standard motor )","00:(Hitachi standard motor )","","00:(Hitachi standard motor )","" "H003","Motor capacity","09:(3.7)","09:(3.7)","kW","09:(3.7)","" "H203","Motor capacity,2nd motor","09:(3.7)","09:(3.7)","kW","09:(3.7)","" "H004","Motor poles setting","00:(2P)","00:(2P)","","01:(4P)","" "H204","Motor poles setting,2nd motor","01:(4P)","01:(4P)","","01:(4P)","" "H005","Motor speed response constant","100","100","%","100","1 ... 1000" "H205","Motor speed response constant, 2nd motor","100","100","%","100","1 ... 1000" "H006","Motor stabilization constant","100","100","","100","0 ... 255" "H206","Motor stabilization constant, 2nd motor","100","100","","100","0 ... 255" "H020","Motor constant R1 (Hitachi motor)","0.385","0.385","Ohm","0.385","0.001 ... 65.535" "H220","Motor constant R1, 2nd motor (Hitachi motor)","0.490","0.490","Ohm","0.490","0.001 ... 65.535" "H021","Motor constant R2 (Hitachi motor)","0.301","0.301","Ohm","0.301","0.001 ... 65.535" "H221","Motor constant R2, 2nd motor (Hitachi motor)","0.352","0.352","Ohm","0.352","0.001 ... 65.535" "H022","Motor constant L (Hitachi motor)","4.21","4.21","mH","4.21","0.01 ... 655.35" "H222","Motor constant L, 2nd motor (Hitachi motor)","5.66","5.66","mH","5.66","0.01 ... 655.35" "H023","Motor constant I0 (Hitachi motor)","5.52","5.52","A","5.52","0.01 ... 655.35" "H223","Motor constant I0, 2nd motor (Hitachi motor)","7.78","7.78","A","7.78","0.01 ... 655.35" "H024","Motor constant J (Hitachi motor)","0.029","0.029","kgm2","0.029","0.001 ... 9999.000" "H224","Motor constant J, 2nd motor (Hitachi motor)","0.055","0.055","kgm2","0.055","0.001 ... 9999.000" "H030","Motor constant R1 (Auto tuned data)","0.385","0.385","Ohm","0.385","0.001 ... 65.535" "H230","Motor constant R1, 2nd motor (Auto tuned data)","0.490","0.490","Ohm","0.490","0.001 ... 65.535" "H031","Motor constant R2 (Auto tuned data)","0.301","0.301","Ohm","0.301","0.001 ... 65.535" "H231","Motor constant R2, 2nd motor (Auto tuned data)","0.352","0.352","Ohm","0.352","0.001 ... 65.535" "H032","Motor constant L (Auto tuned data)","4.21","4.21","mH","4.21","0.01 ... 655.35" "H232","Motor constant L, 2nd motor (Auto tuned data)","5.66","5.66","mH","5.66","0.01 ... 655.35" "H033","Motor constant I0 (Auto tuned data)","5.52","5.52","A","5.52","0.01 ... 655.35" "H233","Motor constant I0, 2nd motor (Auto tuned data)","7.78","7.78","A","7.78","0.01 ... 655.35" "H034","Motor constant J (Auto tuned data)","0.029","0.029","kgm2","0.029","0.001 ... 9999.000" "H234","Motor constant J, 2nd motor (Auto tuned data)","0.055","0.055","kgm2","0.055","0.001 ... 9999.000" "H050","Slip compensation P gain for V/f control with FB","0.20","0.20","times","0.20","0.00 ... 10.00" "H051","Slip compensation I gain for V/f control with FB","2","2","s","2","0 ... 1000" P Group "Data ID","Data Name","Setting value","Current value","Unit","Default value","Range","Comment" "P001","Reaction when option card error occurs","00:(tripping)","00:(tripping)","","00:(tripping)","" "P003","[EA] terminal selection","00:(Speed reference, incl. PID)","00:(Speed reference, incl. PID)","","00:(Speed reference, incl. PID)","" "P004","Pulse train input mode for feedback","00:(Single-phase pulse [EA])","00:(Single-phase pulse [EA])","","00:(Single-phase pulse [EA])","" "P011","Encoder pulse-per-revolution (PPR) setting","512","512","pls","512","32 ... 1024" "P012","Simple positioning selection","00:(simple positioning deactivated)","00:(simple positioning deactivated)","","00:(simple positioning deactivated)","" "P014","Creep pulse ratio","125.0","125.0","%","125.0","0.0 ... 400.0" "P015","Creep speed","5.00","5.00","Hz","5.00","0.50 ... 10.00" "P017","Positioning completion range","50","50","pls","50","0 ... 10000" "P026","Over-speed error detection level","115.0","115.0","%","115.0","0.0 ... 150.0" "P027","Speed deviation error detection level","10.00","10.00","Hz","10.00","0.00 ... 120.00" "P031","Accel/decel time input selection","00:(digital operator)","00:(digital operator)","","00:(digital operator)","" "P033","Torque command input selection","00:(O terminal)","00:(O terminal)","","00:(O terminal)","" "P034","Torque command setting","0","0","%","0","0 ... 200" "P036","Torque bias mode","00:(disabling the mode)","00:(disabling the mode)","","00:(disabling the mode)","" "P037","Torque bias value","0","0","%","0","-200 ... 200" "P038","Torque bias polarity selection","00:(as indicated by the sign)","00:(as indicated by the sign)","","00:(as indicated by the sign)","" "P039","Speed limit for torque-controlled operation (forward rotation)","0.00","0.00","Hz","0.00","0.00 ... 120.00" "P040","Speed limit for torque-controlled operation (reverse rotation)","0.00","0.00","Hz","0.00","0.00 ... 120.00" "P041","Speed / torque control switching time","0","0","ms","0","0 ... 1000" "P044","Communication watchdog timer","1.00","1.00","s","1.00","0.00 ... 99.99" "P045","Inverter action on communication error","00:(tripping)","00:(tripping)","","00:(tripping)","" "P046","DeviceNet polled I/O: Output instance number","1","1","","1","0 ... 20" "P048","Inverter action on communication idle mode","00:(tripping)","00:(tripping)","","00:(tripping)","" "P049","Motor poles setting for RPM","00:(0P)","00:(0P)","","00:(0P)","" "P055","Pulse train frequency scale","25.0","25.0","kHz","25.0","1.0 ... 32.0" "P056","Time constant of pulse train frequency filter","0.10","0.10","s","0.10","0.01 ... 2.00" "P057","Pulse train frequency bias","0","0","%","0","-100 ... 100" "P058","Pulse train frequency limit","100","100","%","100","0 ... 100" "P059","Lower cut off level of the input pulse","1.00","1.00","%","1.00","0.01 ... 20.00" "P060","Multistage position0","0","0","","0","-268435455 ... 268435455" "P061","Multistage position1","0","0","","0","-268435455 ... 268435455" "P062","Multistage position2","0","0","","0","-268435455 ... 268435455" "P063","Multistage position3","0","0","","0","-268435455 ... 268435455" "P064","Multistage position4","0","0","","0","-268435455 ... 268435455" "P065","Multistage position5","0","0","","0","-268435455 ... 268435455" "P066","Multistage position6","0","0","","0","-268435455 ... 268435455" "P067","Multistage position7","0","0","","0","-268435455 ... 268435455" "P068","Homing mode selection","00:(Low speed mode)","00:(Low speed mode)","","00:(Low speed mode)","" "P069","Homing direction","01:(RV)","01:(RV)","","01:(RV)","" "P070","Low-speed homing frequency","5.00","5.00","Hz","5.00","0.50 ... 10.00" "P071","High-speed homing frequency","5.00","5.00","Hz","5.00","0.00 ... 300.00" "P072","Position range (forward)","268435455","268435455","","268435455","0 ... 268435455" "P073","Position range (reverse)","-268435455","-268435455","","-268435455","-268435455 ... 0" "P075","Positioning mode","00:(With limitation)","00:(With limitation)","","00:(With limitation)","" "P077","Encoder disconnection timeout","1.0","1.0","s","1.0","0.0 ... 10.0" "P080","Positioning restart range","0","0","pls","0","0 ... 10000" "P081","Store position at power off selection","00:(Not store)","00:(Not store)","","00:(Not store)","" "P082","Current position at power off","0","0","","0","-268435455 ... 268435455" "P083","Preset position data","0","0","","0","-268435455 ... 268435455" "P100","EzSQ user parameter U(00)","0","0","","0","0 ... 65535" "P101","EzSQ user parameter U(01)","0","0","","0","0 ... 65535" "P102","EzSQ user parameter U(02)","0","0","","0","0 ... 65535" "P103","EzSQ user parameter U(03)","0","0","","0","0 ... 65535" "P104","EzSQ user parameter U(04)","0","0","","0","0 ... 65535" "P105","EzSQ user parameter U(05)","0","0","","0","0 ... 65535" "P106","EzSQ user parameter U(06)","0","0","","0","0 ... 65535" "P107","EzSQ user parameter U(07)","0","0","","0","0 ... 65535" "P108","EzSQ user parameter U(08)","0","0","","0","0 ... 65535" "P109","EzSQ user parameter U(09)","0","0","","0","0 ... 65535" "P110","EzSQ user parameter U(10)","0","0","","0","0 ... 65535" "P111","EzSQ user parameter U(11)","0","0","","0","0 ... 65535" "P112","EzSQ user parameter U(12)","0","0","","0","0 ... 65535" "P113","EzSQ user parameter U(13)","0","0","","0","0 ... 65535" "P114","EzSQ user parameter U(14)","0","0","","0","0 ... 65535" "P115","EzSQ user parameter U(15)","0","0","","0","0 ... 65535" "P116","EzSQ user parameter U(16)","0","0","","0","0 ... 65535" "P117","EzSQ user parameter U(17)","0","0","","0","0 ... 65535" "P118","EzSQ user parameter U(18)","0","0","","0","0 ... 65535" "P119","EzSQ user parameter U(19)","0","0","","0","0 ... 65535" "P120","EzSQ user parameter U(20)","0","0","","0","0 ... 65535" "P121","EzSQ user parameter U(21)","0","0","","0","0 ... 65535" "P122","EzSQ user parameter U(22)","0","0","","0","0 ... 65535" "P123","EzSQ user parameter U(23)","0","0","","0","0 ... 65535" "P124","EzSQ user parameter U(24)","0","0","","0","0 ... 65535" "P125","EzSQ user parameter U(25)","0","0","","0","0 ... 65535" "P126","EzSQ user parameter U(26)","0","0","","0","0 ... 65535" "P127","EzSQ user parameter U(27)","0","0","","0","0 ... 65535" "P128","EzSQ user parameter U(28)","0","0","","0","0 ... 65535" "P129","EzSQ user parameter U(29)","0","0","","0","0 ... 65535" "P130","EzSQ user parameter U(30)","0","0","","0","0 ... 65535" "P131","EzSQ user parameter U(31)","0","0","","0","0 ... 65535" "P140","EzCOM number of data","5","5","","5","1 ... 5" "P141","EzCOM destination 1 adderss","1","1","","1","1 ... 247" "P142","EzCOM destination 1 register","0","0","","0","0 ... 65535" "P143","EzCOM source 1 register","0","0","","0","0 ... 65535" "P144","EzCOM destination 2 adderss","2","2","","2","1 ... 247" "P145","EzCOM destination 2 register","0","0","","0","0 ... 65535" "P146","EzCOM source 2 register","0","0","","0","0 ... 65535" "P147","EzCOM destination 3 adderss","3","3","","3","1 ... 247" "P148","EzCOM destination 3 register","0","0","","0","0 ... 65535" "P149","EzCOM source 3 register","0","0","","0","0 ... 65535" "P150","EzCOM destination 4 adderss","4","4","","4","1 ... 247" "P151","EzCOM destination 4 register","0","0","","0","0 ... 65535" "P152","EzCOM source 4 register","0","0","","0","0 ... 65535" "P153","EzCOM destination 5 adderss","5","5","","5","1 ... 247" "P154","EzCOM destination 5 register","0","0","","0","0 ... 65535" "P155","EzCOM source 5 register","0","0","","0","0 ... 65535" "P160","Option I/F command register to write 1","0","0","","0","0 ... 65535" "P161","Option I/F command register to write 2","0","0","","0","0 ... 65535" "P162","Option I/F command register to write 3","0","0","","0","0 ... 65535" "P163","Option I/F command register to write 4","0","0","","0","0 ... 65535" "P164","Option I/F command register to write 5","0","0","","0","0 ... 65535" "P165","Option I/F command register to write 6","0","0","","0","0 ... 65535" "P166","Option I/F command register to write 7","0","0","","0","0 ... 65535" "P167","Option I/F command register to write 8","0","0","","0","0 ... 65535" "P168","Option I/F command register to write 9","0","0","","0","0 ... 65535" "P169","Option I/F command register to write 10","0","0","","0","0 ... 65535" "P170","Option I/F command register to read 1","0","0","","0","0 ... 65535" "P171","Option I/F command register to read 2","0","0","","0","0 ... 65535" "P172","Option I/F command register to read 3","0","0","","0","0 ... 65535" "P173","Option I/F command register to read 4","0","0","","0","0 ... 65535" "P174","Option I/F command register to read 5","0","0","","0","0 ... 65535" "P175","Option I/F command register to read 6","0","0","","0","0 ... 65535" "P176","Option I/F command register to read 7","0","0","","0","0 ... 65535" "P177","Option I/F command register to read 8","0","0","","0","0 ... 65535" "P178","Option I/F command register to read 9","0","0","","0","0 ... 65535" "P179","Option I/F command register to read 10","0","0","","0","0 ... 65535" "P180","Profibus Node address","0","0","","0","0 ... 125" "P181","Profibus Clear Node address","00:(clear)","00:(clear)","","00:(clear)","" "P182","Profibus Map selection","00:(PPO Type)","00:(PPO Type)","","00:(PPO Type)","" "P185","CANopen Node address","0","0","","0","0 ... 127" "P186","CAN open communication speed","06:(500kbps)","06:(500kbps)","","06:(500kbps)","" "P190","CompoNet Node address","0","0","","0","0 ... 63" "P192","DeviceNet MAC ID","63","63","","63","0 ... 63" "P195","ML2 frame length","00:(32bytes)","00:(32bytes)","","00:(32bytes)","" "P196","ML2 Node address","33","33","","33","33 ... 62" "P900","Half / All period select of 1ph Enc. Input","00:(Half period)","00:(Half period)","","00:(Half period)","" "P901","Time const. for enc. speed detection","20","20","ms","20","0 ... 9999" Trip Monitor "Data ID","Data Name","Setting value","Current value","Unit","Default value","Range","Comment" "d080","Trip Counter","0","0","time","0","0 ... 99999" "d081_0","Trip info. 1 (factor)","00:(No trip factor)","00:(No trip factor)","","00:(No trip factor)","" "d081_1","Trip info. 1 (inverter status)","00:(Resetting)","00:(Resetting)","","00:(Resetting)","" "d081_2","Trip info. 1 (frequency)","0.00","0.00","Hz","0.00","0.00 ... 400.00" "d081_3","Trip info. 1 (current)","0.00","0.00","A","0.00","0.00 ... 655.30" "d081_4","Trip info. 1 (voltage)","0.0","0.0","V","0.0","0.0 ... 1000.0" "d081_5","Trip info. 1 (running time)","0","0","hr","0","0 ... 1193028" "d081_6","Trip info. 1 (power-on time)","0","0","hr","0","0 ... 1193028" "d082_0","Trip info. 2 (factor)","00:(No trip factor)","00:(No trip factor)","","00:(No trip factor)","" "d082_1","Trip info. 2 (inverter status)","00:(Resetting)","00:(Resetting)","","00:(Resetting)","" "d082_2","Trip info. 2 (frequency)","0.00","0.00","Hz","0.00","0.00 ... 400.00" "d082_3","Trip info. 2 (current)","0.00","0.00","A","0.00","0.00 ... 655.30" "d082_4","Trip info. 2 (voltage)","0.0","0.0","V","0.0","0.0 ... 1000.0" "d082_5","Trip info. 2 (running time)","0","0","hr","0","0 ... 1193028" "d082_6","Trip info. 2 (power-on time)","0","0","hr","0","0 ... 1193028" "d083_0","Trip info. 3 (factor)","00:(No trip factor)","00:(No trip factor)","","00:(No trip factor)","" "d083_1","Trip info. 3 (inverter status)","00:(Resetting)","00:(Resetting)","","00:(Resetting)","" "d083_2","Trip info. 3 (frequency)","0.00","0.00","Hz","0.00","0.00 ... 400.00" "d083_3","Trip info. 3 (current)","0.00","0.00","A","0.00","0.00 ... 655.30" "d083_4","Trip info. 3 (voltage)","0.0","0.0","V","0.0","0.0 ... 1000.0" "d083_5","Trip info. 3 (running time)","0","0","hr","0","0 ... 1193028" "d083_6","Trip info. 3 (power-on time)","0","0","hr","0","0 ... 1193028" "d084_0","Trip info. 4 (factor)","00:(No trip factor)","00:(No trip factor)","","00:(No trip factor)","" "d084_1","Trip info. 4 (inverter status)","00:(Resetting)","00:(Resetting)","","00:(Resetting)","" "d084_2","Trip info. 4 (frequency)","0.00","0.00","Hz","0.00","0.00 ... 400.00" "d084_3","Trip info. 4 (current)","0.00","0.00","A","0.00","0.00 ... 655.30" "d084_4","Trip info. 4 (voltage)","0.0","0.0","V","0.0","0.0 ... 1000.0" "d084_5","Trip info. 4 (running time)","0","0","hr","0","0 ... 1193028" "d084_6","Trip info. 4 (power-on time)","0","0","hr","0","0 ... 1193028" "d085_0","Trip info. 5 (factor)","00:(No trip factor)","00:(No trip factor)","","00:(No trip factor)","" "d085_1","Trip info. 5 (inverter status)","00:(Resetting)","00:(Resetting)","","00:(Resetting)","" "d085_2","Trip info. 5 (frequency)","0.00","0.00","Hz","0.00","0.00 ... 400.00" "d085_3","Trip info. 5 (current)","0.00","0.00","A","0.00","0.00 ... 655.30" "d085_4","Trip info. 5 (voltage)","0.0","0.0","V","0.0","0.0 ... 1000.0" "d085_5","Trip info. 5 (running time)","0","0","hr","0","0 ... 1193028" "d085_6","Trip info. 5 (power-on time)","0","0","hr","0","0 ... 1193028" "d086_0","Trip info. 6 (factor)","00:(No trip factor)","00:(No trip factor)","","00:(No trip factor)","" "d086_1","Trip info. 6 (inverter status)","00:(Resetting)","00:(Resetting)","","00:(Resetting)","" "d086_2","Trip info. 6 (frequency)","0.00","0.00","Hz","0.00","0.00 ... 400.00" "d086_3","Trip info. 6 (current)","0.00","0.00","A","0.00","0.00 ... 655.30" "d086_4","Trip info. 6 (voltage)","0.0","0.0","V","0.0","0.0 ... 1000.0" "d086_5","Trip info. 6 (running time)","0","0","hr","0","0 ... 1193028" "d086_6","Trip info. 6 (power-on time)","0","0","hr","0","0 ... 1193028" "d090","Warning monitor","00:Warning code","00:Warning code","","00:Warning code",""